Telegram part
Description
Variable
Length Values CoLa A (ASCII)
Values CoLa B (binary)
Time info Year
1970 to 2037
Uint_16
2
7B2h
...
7F5h
07 B2
...
07 F5
Month
1 to 12
Uint_8
1
1
…
C
01
…
0C
Day
Day of month 1 to 31 Uint_8
1
1
…
1Fh
01
…
1F
Hour
0 to 23
Uint_8
1
0
…
17h
00
…
17
Minute
0 to 59
Uint_8
1
0
…
3Bh
00
…
3B
Second
0 to 59
Uint_8
1
0
…
3Bh
00
…
3B
Microsec‐
ond
0 to 999999
Uint_32
4
0h
...
F423Fh
00 00 00 00
…
00 0F
42 3F
Event info
Display event info
Uint_16
2
No info:
0
No info:
00 00
1
Does not count how many telegrams were really given out; is relevant if not all scans are delivered from the scan core.
LMDscandata - reserved values
Distance values are only valid starting from 16d and higher. Lower values have the following meaning:
DIST
RSSI
Description
0d
0h
Invalid measurement value; caused by very low remission (extremely dark object), object distance
not within measurement range (too close or too far away) or selected filter settings at device
1d
FFFFh
(16Bit out‐
put)
Invalid measurement value, device was dazzled or blinded, e.g. by measuring on reflector
4d
–
15d
0h
Reserved, currently not in use
≥
16d
>
0h
Valid measurement values
12.2
EU declaration of conformity / Certificates
The EU declaration of conformity and other certificates can be downloaded from the
Internet at:
•
12.3
Licenses
SICK uses open source software which is published by the rights holders under a free
license. Among others, the following license types are used: GNU General Public
License (GPL version 2, GPL version 3), GNU Lesser General Public License (LGPL), MIT
license, zlib license and licenses derived from the BSD license.
This program is provided for general use without warranty of any kind. This warranty dis‐
claimer also extends to the implicit assurance of marketability or suitability of the pro‐
gram for a particular purpose.
More details can be found in the GNU General Public License. View the complete
license texts here:
. Printed copies of the license texts are
also available on request.
12
ANNEX
56
O P E R A T I N G I N S T R U C T I O N S | LMS4400/LMS4500
8023202/16S6/2020-01-24 | SICK
Subject to change without notice