OPERATION
8
Operation
8.1
Display and pushbuttons
All lengths specified in the menu refer to the end of the probe and/or with a configured
offset (see
) to the tank bottom. You can access the menu by
pressing the SET pushbutton for at least three seconds.
8.1.1
Variants with two switching outputs
1000 mm
39,4 in
Q1 Q2
Arrow pushbuttons:
For navigating in the menu and changing values
Set pushbutton:
For saving and confirming
Esc pushbutton:
To exit the operating menu one step at a time
Note:
The status of the switching outputs is indicated in millimeters by the bars above the
unit symbol. This display is not available when inches are selected as the unit.
8.1.2
Variants with four switching outputs
1000 mm
39,4 in
Q1/2/3/4
Arrow pushbuttons:
For navigating in the menu and changing values
Set pushbutton:
For saving and confirming
Esc pushbutton:
To exit the operating menu one step at a time
8.1.3
IO-Link
For operation via IO-Link, an IODD file and a description of the available telegram
parameters can be downloaded from