O P E R AT I N G I N S T R U C T I O N S | L F P I N OX
8019921/15H0 / 2019-09-30| S I C K A G
Irrtümer und Änderungen vorbehalten
5 5
14
TECHNICAL DATA
14.3
Mechanical/materials
Wetted parts
1.4404 (Ra ≤ 0.8 μm), PEEK
Process connection
G 3/4 (hygienic process connectors with adapter
for G 3/4, see accessories), 3/4 NPT
Housing material
1.4305
Max. probe load
6 Nm
Enclosure rating
IP67: EN 60529, IP69K: EN 40050
Coaxial cable insulation
FEP
Electrical cable insulation
1)
PVC
1)
Version with electrical cable instead of M12 connection.
14.4
Reference conditions
Container with diameter
1
m
Minimum distance to built-in compo-
nents
>
300
mm
Distance from end of probe to tank
bottom
>
15
mm
Air humidity
65
% ±
20
%
Temperature
+20 °C ±
5 °C
Pressure
1,013
mbar abs. ±
20
mbar
Medium
Water, DK = 80
Centered installation of sensor
Container parameterization carried out
14.5
Ambient conditions
Ambient temperature, operation
1)
–20 °C ... + 60 °C
Ambient temperature, storage
–40 °C ... +80 °C
Ambient temperature, coaxial cable
–20 °C ... + 60 °C
1)
According to UL listing: degree of contamination 3 (UL61010-1: 2012-05); air humidity:
80% at temperatures up to 31 °C; installation height: max. 3,000 m above sea level; indoor
applications only