5.4
Mounting the device
NOTICE
Damage to device due to improper mounting
Screw M3 screws through the through hole. Screws with a larger thread diameter
damage the device.
•
Do not screw the M4 screws right through to the other side of the device!
•
To fasten the device, carefully screw only M3 screws (length: min 35 mm) into
the through holes on opposite sides of the device.
1.
Mount the device in a suitably prepared mounting system using the threaded
mounting holes provided.
°
Mount the device on a mounting system using M4 screws. Screw the screws
no more than 5 mm into the threaded mounting holes or sliding nuts. Use the
threaded mounting holes in pairs on the left and right side of the device.
°
For alternative mounting, carefully screw the 2 M3 screws (length: min
35 mm) into the through holes on opposite sides of the device. Use the
threaded mounting holes in pairs on the left and right side of the device.
°
Optional: attach the separately ordered SICK mounting system to the device.
Mounting systems are available as accessories,
.
2.
Align the device taking into consideration the field of view (
values during operation", page 48
) and the application circumstances (
"Installation requirements", page 19
).
3.
Connect the device to interfaces and supply voltage when disconnected from
voltage,
see "Connecting the device", page 31
✓
The
Ready
status LED lights up green.
4.
Perform fine adjustment.