Alpha mounting angle (
α
)
–y
+y
–x
+x
1
2
4
5
α = 270°
α = 180°
α = 0°
3
α = 90°
Figure 9: Mounting bracket
α
1
Coordinate system of the field of view
2
Angle
α
= 0° (default value), direction of motion according to + x
3
Angle
α
= 90°, direction of motion according to + y
4
Angle
α
= 180°, direction of motion according to - x
5
Angle
α
= 270°, direction of motion according to - y
5.3.4
Adjusting focus with the focus adjustment tool
Overview
The user adjusts the focus position to suit the required working distance with the help
of the focus adjustment tool. The focus position is valid for one working distance. The
device does not perform automatic tracking (auto focus) if, for example, the working
distance changes significantly. The focus adjustment tool is included with delivery.
Important information
NOTICE
Risk of product damage
If the focus adjustment tool is turned with too much force, the device will be damaged.
■
Observe maximum tightening torque.
MOUNTING