Status information for external device monitoring (EDM)
Jump addresses that illustrate the status of the safety outputs can be found on the
Safe
Outputs
page. These can be used for retroactive implementation of external device mon‐
itoring.
Table 41: Assignment of jump addresses to the safety outputs
Jump address
Safety output
Stop_Request
K100.1 Q4 stop request
STO_enable
K100.1 Q1 STO
K100.1 Q2 STO
Brake_enable
K100.3 Q1 Brake
K100.3 Q2 Brake
7.5
Contents of the CPU logic
The logic editor contains the following pages:
Table 42: Logic editor overview
Page name
Contents
Disclaimer
Disclaimer and safety notes
Interface
Configuration of safe stop request, safely limited speed
(SLS) request, and override function request
Safe Position and Diagnostics
Diagnostics measures used to determine the safe posi‐
tion
Stop/reset/restart
Configuration of reset and restart
Safe Outputs
Configuration of safe stop
The logic editor uses the following safety application function blocks (SAPP-FBs):
•
Plausibility test SAPP-FB
•
Sensor2 test SAPP-FB
•
Sensor ID SAPP-FB
•
Safe Position 1 SAPP-FB
•
Safe Stop outputs SAPP-FB
•
Safe Stop reset SAPP-FB
The SAPP-FBs are protected with a password. The settings in the function blocks are
not displayed and cannot be changed.
7.5.1
Disclaimer page
This page contains the disclaimer, the version number, and a short description of the
application.
7
CONFIGURATION
54
O P E R A T I N G I N S T R U C T I O N S | Safe Linear Positioning
8020941/12O9/2019-08-05 | SICK
Subject to change without notice