Operating instructions Distance sensors Dx35
Electrical connection
24
© SICK AG • Subject to change without notice • 8014868/YEF7/2014-09-02
7
Electrical connection
7.1
Safety
Incorrect supply voltage
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to
the equipment.
For this reason:
• Operate the distance sensor using only safety extra-
low voltage.
• The power supply must ensure safe electrical isolation
(SELV/PELV) and limit the current to a maximum of 8 A.
Working with live parts
NOTICE
Equipment damage or unpredictable operation due to
working with live parts!
Working with live parts may result in unpredictable
operation.
For this reason:
• Only carry out wiring work when the power is off.
• Only connect and disconnect cable connections when
the power is off.
7.2
Wiring notes
NOTICE
Faults due to incorrect wiring!
Incorrect wiring may result in operational faults.
For this reason:
• Follow the wiring notes precisely.
NOTE
We recommend using pre-assembled cables for
the wiring.
→
For pre-assembled cables, see Page 60,
Chapter 14.1.