8014868/YEF7/2014-09-02 • © SICK AG • Subject to change without notice 29
Operating instructions Distance sensors Dx35
Commissioning
Q1 far or Q2 far
(continued)
Example: One-point teach is to be performed for the switching output Q1.
1. Position object at teach point
1
.
2. Press and hold the
select
pushbutton for longer than 5 seconds. The
Q1
near
LED lights up.
3. Press the
select
pushbutton. The
Q1 far
LED lights up.
Press the
set
pushbutton.
If the teach was successful, the setting is applied immediately.
The
Q1
and
Q2
LEDs flash twice simultaneously. If the teach was not
successful, the
Q1
and
Q2
LEDs flash alternately.
4.
If necessary, perform fine teach.
→
See Page 34, Chapter 8.3.
5.
In order to leave teach mode, either press and hold the
select
pushbutton longer than 5 seconds or wait 5 minutes without pressing
the pushbuttons.
8.1.2
Performing window (Wnd) teach
Window (Wnd)
The switching output is set when the object is located within the configured
window.
In the range below 50 mm, the switching behavior is dependent on
the signal quality.
near < far
(non-inverted behavior)
Dx
35
Min
Max
1
1
0
2
Fig. 11: Setting switching points for window (non-inverted behaviour)
1
Teach point near, position
1
2
Teach point far, position
2
Example: Window teach is to be performed for the switching output Q1.
1. Position object at teach point
1
.
2. Press and hold the
select
pushbutton for longer than 5 seconds. The
Q1
near
LED lights up.
3. Press the
set
pushbutton.
If the teach was successful, the setting is applied immediately. The
Q1
and
Q2
LEDs flash twice simultaneously. If the teach was not success
-
ful, the
Q1
and
Q2
LEDs flash alternately.
4.
If necessary, perform fine teach.
→
See Page 34, Chapter 8.3.