8014868/YEF7/2014-09-02 • © SICK AG • Subject to change without notice 41
Operating instructions Distance sensors Dx35
IO-Link interface
Other settings
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
84 (0x54)
User tag 1
UINT32
R/W
32 bits
–
85 (0x55)
User tag 2
UINT16
R/W
16 bits
–
40 (0x28)
Process data
UINT16
R
16 bits
Content depends on
"process data" setting
Table 14: IO-Link-specific service data – other settings
9.3.2
SICK-specific – outputs
NOTE
In the following tables, the factory settings are indicated
in bold in the "Value range" or "Example" columns.
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
69 (0x45)
Q1 switching
function
UINT8
R/W
• 0: DtO
(Distance to
Object)
• 1: ObSB (Object
between Sensor
and Background)
• 2: Window
• 3: VMA (signal level
warning)
• 4: Alarm (fault
output)
0
70 (0x46)
Q1 switching point
near
UINT16
R/W
50 … 50000 mm
–
In 1 mm steps
72 (0x48)
Q1 switching point
far
UINT16
R/W
50 … 50000 mm
DT35/DS35:
10000
DL35/DR35:
35000
In 1 mm steps
71 (0x47)
Q1 hysteresis near
UINT16
R/W
0 … 49550 mm
25
In 1 mm steps
73 (0x49)
Q1 hysteresis far
UINT16
R/W
0 … 49550 mm
25
In 1 mm steps
94 (0x5E)
Q1 near-far center-
ing
UINT16
R/W
50 … 50000 mm
–
In 1 mm steps
92 (0x5C)
Q2 output function
UINT8
R/W
• 0: 4 … 20 mA
• 1: 0 … 10 V
• 2: Switching
DT35/DL35: 0
DS35/DR35:
–