Operating Instructions
Chapter
5
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-21
Electrical installation
5.5.4
Connecting the host interface
Risk of damage to the interface module
Electrical components in the CLV may be damaged if the host interface is connected
incorrectly.
¾
Connect the host interface as shown in
.
¾
Check the connections carefully before you switch on the CLV.
¾
Connect the host interface on the CLV to the host using shielded cables (EMC require-
ments). Ensure that the maximum cable lengths are not exceeded (see
).
Default
In the default setting, the CLV communicates with the host via the host interface using the
values shown in
.
Fig. 5-3:
Connecting the host interface
RS 232
RS 422
( )= 9-pin D-Sub-
connector at PC
CAN-Network:
Connection diagram for SICK CAN Scanner Network
see "CLV Connect" program on CD-ROM
( )=9-pin Sub D
plug on PC
Parameter Value
Physical design
RS 422/485
Data transfer rate
9,600 bd
Data bits
8
Parity None
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for repeat:
none, timeout: 50 ms)
Table 5-24: Communication parameters for the host interface (default setting)