Operation
parameterizable tolerance range in conveying direction between two objects at the end and
beginning of each object makes it easier to assign the reading results to the individual
objects.
As soon as a successful reading has been made, the CLV sends the reading result and
object assignment (object number and position of the bar code(s) on the object in conveying
direction) to the OTC 400 via the CAN bus. The OTC 400 then compiles the results with the
same name (identical bar-code contents) received from all the slaves and sends this filtered
overall reading result for each object to the host at a defined output time during the reading
process. The object release point (data output) parameterized in the OTC 400 marks the
end of the reading field. The object release point parameterized in the CLV must always be
smaller than that of the OTC 400. The parameter setting for the focus release point depends
on whether the CLV is used as part of a group and on its position relative to the conveyor
belt. The focus release point is the point in the reading field at which the CLV permits a new
focus switchover when the tracked object has passed this point, even if the number of bar
codes to be read has not yet been reached.
Parameterizing slave mode in the CLV:
OTC 400 Controller:
Beside other functions parameterize the following function in the OTC 400:
For further function to be parameterized in the OTC 400 see the "
OTS 400 Omni Tracking
System"
Operating instructions (order no. 8 008 869, English edition).
Action
Settings in CLV-Setup
Parameterize CAN interface
Ö
CAN I
NTERFACE
tab
Ö
CAN I
NTERFACE
F
UNCTION
section
– OTS slave
Ö
CAN D
ATA
R
ATE
section
– 500 kBit/s
Table 6-21: Guide: Parameterizing slave mode in the CLV for object tracking mode with OTC 400
Action
Settings in CLV-Setup
Pameterize operation mode in
the OTC 400 (master)
Ö
D
EVICE
CONFIGURATION
tab
Ö
R
EADING
T
RIGGER
P
ARAMETERS
button
Ö
O
PERATING
MODE
section
– Increment controlled (Tracking)
Table 6-22: Guide: Parameterizing tracking mode in the OTC 400