Operating Instructions
Chapter
10
CLP 100 Bar Code Reader
Appendix
8 008 912/0000/21-08-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
43
Selection of a bar code (example):
2/5 ITF
6-digit
without check digit
<STX>U0B3N6D0C0<CR>
LED Control
UI
0: CCD ON (Red) & READING GATES ON (Green)
1: NO READ (Red) & GOOD READ (Green)
Minimum Time
Between Labels
UD
0: NOT READ
nn: 01-99 = Prohibition Time 10-990 ms
Code Comparison
UN
0: NO
1: YES
Sensor Input
A
0: LEVEL
0,mm: EDGE mm s (mm = 1-60 ms)
1: OFF
Operation Mode
UC
0: READING MODE
1: DIAGNOSIS MODE
2: ONLINE TESTING MODE
3: ADJUSTMENT MODE
Result Output On
Code Comparison
UQ
0: ACTIVE HIGH ON READ & MATCH
1: ACTIVE HIGH ON READ & NO MATCH
Teach In Code
Comparison
UR
0: NO
1: YES
Read Out
W
0: VERSION INFORMATION
4: BAUD RATE/FRAME (1 STOP)
5: BAUD RATE/FRAME (2 STOP)
Parameter
Character
Value
Tab. 10-3: Command language for CLP bar code readers