FAULT DIAGNOSIS
8
75
8023732/2018-09-10|SICK
Subject to change without notice
O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | AOS301-WWD
A site error is displayed in the menu bar if there is an error (red symbol) on at least one of
the subordinate levels.
•
If the AOS301-WWD is only ready for operation to a limited extent, the
Site
workspace
is highlighted in red font with a red exclamation mark.
•
On the right-hand side, the following information message is displayed in red:
Configuration is running with error(s)
.
•
Warnings do not affect the site level.
Road
Display
Possible cause
Possible measures
Lane red
(navigation
tree)
•
An error has occurred at a
subordinate level
▸
Check the live view or
navigation tree to see which
component is causing the
error.
Radar sensor
Display
Possible cause
Possible measures
Housing
red
•
Radar sensor supply voltage
missing or too low
•
Ethernet connection to the
radar sensor interrupted.
•
Radar sensor defective.
▸
Check the voltage supply.
▸
Check the Ethernet
connection.
▸
Replacing the device
System functions without devices
* No status indicator; symbol is always green
Plug-ins
Display
Possible cause
Possible measures
TDC-E IO plug-in
red
•
Rule could not be applied
to an object
•
Connection to the TDC-E
HardwareManager not
possible.
▸
Check rule file.
▸
Check connection settings
MQTT
plug-in red
•
Rule could not be applied
to an object
•
Connection to the TDC-E
HardwareManager not
possible.
▸
Check rule file.
▸
Check connection settings
Fault indicators at site
level
Fault display on other
levels