Tools
Depending on the selected view, different tools are available to help you perform
configurations or customize the display.
The following are examples of some of the tools for customizing the display:
•
Button
: Display fields in the polar coordinates system.
•
Button
: Change over the view of the device/fields. Device black: View from
above, device blue: View from below.
•
Button
or
: Switch off display of the full measuring line or display measur‐
ing line as dotted.
7.1.1
Parameter - network
The network area has input screens for configuring the Ethernet connection, the digital
inputs / digital outputs and the device.
For Ethernet configuration, note that the IP-Address / subnet-mask must correspond
with the address space of the subsequent application.
Table 10: IP-Address factory setting
Parameter
Value
IP-Address
192.168.0.1
Subnet mask
255.255.255.0
7.1.2
Parameter - filters
When selecting the filter, consider filter mutual interference,
7.2
Field evaluation
If the field shape of field set 1 has been taught in without a computer using the teach-in
pushbutton, SOPAS is generally used to continue the configuration.
This includes the following:
•
Setting of field shapes/sizes and, if applicable, non-programmable field sets
based on the default setting and the setting of response time of the fields
•
Setting of the blanking size and the holding time of the assigned digital outputs
OUT 1 ... OUT 3
7.2.1
Teach-in / Field set selection
For the field evaluation application, it is possible to configure the device as follows
rather than configuring it via SOPAS:
•
Selection of one of 16 field sets, each with 3 fields of the same size nested into
one another, by means of input wiring.
•
Teach-in of the surrounding contour to automatically generate the outer field with
any shape, including more complex shapes, and to deduce the two inner fields.
The field sets are organized into groups in segmented field shapes. The shape can be
changed at will, the default is rectangular.
In the factory setting, the 3 origin-oriented fields of a field set are nested inside
one another. The size of field 2 corresponds to field 1 plus 25%. The size of field 3
corresponds to field 1 plus 52%.
7
OPERATION
38
O P E R A T I N G I N S T R U C T I O N S | TiM781
8024231/1G72/2022-05-27 | SICK
Subject to change without notice