6.4.1
TiMxxx-21xxxxx
“Power/I/O” connection
3
1
7
2
6
5
4
8
9
10
12
11
Table 8: Male connector, M12, 12-pin, A-coded
Pin
Signal
Function
Wire colors of connecting
cable with flying leads
1)
1
GND
Ground
Blue
2
V
S
Supply voltage
Brown
3
IN 1
Digital input 1 (field set selection)
Red
4
IN 2
Digital input 2 (field set selection)
Green
5
OUT 1
Digital output 1 (object detection)
Pink
6
OUT 2
Digital output 2 (object detection)
Yellow
7
OUT 3
Digital output 3 (object detection)
Black
8
OUT 4
Digital output 4 (index/error)
Gray
9
IN
GND
Common ground for all inputs
White
10
IN 3
Digital input 3 (field set selection)
Violet
11
IN 4
Digital input 4 (field set selection)
Gray and pink
12
–
Reserved, do not wire this PIN!
Rot and blue
–
–
Screen
–
1)
Example values when using the connecting cables part numbers 6054974 (5 m), 6054973 (10 m),
6054972 (20 m). Signal assignment and wire colors can vary when using other connecting cables.
"Ethernet" connection
1
4
3
2
Table 9: Female connector, 4-pin, D-coded
Contact
Labeling
Description
1
TX+
2
RX+
R
3
TX-
Sender-
4
RX-
Receiver-
6.4.2
USB interface
The Ethernet interface is recommended as a communication interface.
If using the USB interface, please note:
•
Use a high-speed USB cable, maximum length of cable: 3 m.
•
The connection may be interrupted due to ESD/EMC influences. If necessary:
Disconnect USB cable from the device, then reconnect it. Restart communication
via SOPAS ET software (“Online” button).
ELECTRICAL INSTALLATION
6
8024231/1G72/2022-05-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM781
33