18
DST2600 User’s Manual
On the second row are shown the three mains phase-to-phase voltages, L1-L2, L2-
L3, L3-L1. The measurements are in volts wit no decimals. For single-phase system,
the second and the third measurement are substituted with dashes, and the first shows
the phase-to-neutral voltage. On the right side there is shown the mains frequency, in
hertz, with one decimal digit.
In “MODE 3”, pressing more times the “AUX/PROGRAM” key, it is possible to visualize three
different pages containing measurements related to the engine:
-
Page 1:
On second row there are visualized the total engine starts number (only when the
engine was really started), both manual and automatic, and the engine start battery
voltage, in volts with one decimal digit. The start counter can be reset
-
Page 2
On second row there are visualized three counters related to the engine running hours.
On the left side there is the total engine running hours (absolute hours), in the centre
the partial engine running hours and on the right side the engine running hours missing
before the engine maintenance (this function must be set with parameter P.424,
otherwise dashes are shown).
-
Page 3
On second row are shown in the order: the engine oil pressure (in bar), the coolant
temperature (in °C) and the fuel level (as percentage with respect the full tank).
These measurements are available only if engine instruments were been
properly configured
. If one or more measurement is not available because not
configured, the indication is substituted with dashes
START#/ BATTERY
224 13.4Vdc
HOUR ABS/PAR/MIS
51 48 -------
Bar °C Lev%
3.8 82 32