Menu path: IR
PRESETS > GOOSENECK
/
BOUNDARY >
MUTE
BUTTON
BEHAVIOR
Note: When the mute/active button is set to Disabled, the
transmitter will still send TPCI data if the button is pressed.
High-Pass Filter
Each transmitter contains a high-pass filter.
The high-pass filter:
attenuates frequencies below 150 Hz by 12 dB per
octave
reduces low-frequency noise caused by table
vibration or air handling systems
Adjust high-pass filter settings using Wireless Workbench
or the receiver front panel.
Menu path: IR
PRESETS > GOOSENECK
/
BOUNDARY >
HIGH
PASS
Transmitter RF Power
Reference the following table for setting RF Power:
RF Power Setting System Range
Application
1 mW
33 m (100 ft.)
For increased channel
reuse at close
distances
10 mW
100 m (330 ft.)
Typical setups
20 mW
>100 m (330 ft.) For hostile RF
environments or long-
distance applications
Menu path: IR
PRESETS > GOOSENECK
/
BOUNDARY >
RF
POWER
Note: Using the 20 mW setting decreases the transmitter battery