background image

AutoGate™

P/N 1128479 Rev. A

Thank you for buying this product from Shur-Co

®

. We appreciate your 

confidence in our products. Please read and thoroughly understand 

this manual before installing and/or operating this system.
Pay particular attention to important safety and operating instructions, 

as well as warnings and cautions. The hazard symbol         is used to 

alert users to potentially hazardous conditions and is followed by cau

-

tion, warning or danger messages.
Failure to READ AND FOLLOW INSTRUCTIONS could result in fail

-

ure of your system and/or personal injury. Your trailer requirements 

may, however, call for minor variations to these instructions.
Please inspect your system periodically. Repair or replace worn or 

damaged parts to your system.

QUESTIONS? CALL OUR HELP LINE:

1-866-748-7435

MON-FRI 8 AM-5 PM CENTRAL TIME

!

Mounting Hardware

 ............................................................................1

System Components ..........................................................................2

Stop Plate and Brackets Installation 

 ...............................................3-4

Control Box Installation

 .......................................................................

5

Actuator Installation

 ............................................................................6

Trickle Charger Installation

 .................................................................7

Final Adjustments

 ...............................................................................8

Replacement Parts

 .............................................................................9

We at Shur-Co

®

 are concerned with your safety and the safety of all 

those operating this system. Therefore, we have provided safety de

-

cals at various locations on your system. Keep decals as clean as pos

-

sible at all times. Replace any decal that has become worn or dam

-

aged, painted over or otherwise difficult to read. Replacement decals 

are available through Shur-Co

®

 dealers.

TABLE OF CONTENTS

MESSAGE TO OWNERS

SAFETY

1.  Electric Drill

2.  Air or Electric Impact Wrench

3.  Sockets - 5/16", 1/2", 9/16", 17mm

4.  Nut Driver - 5/16"

5.  Hand Wire Crimper

6.  Wire Stripper

7.  Voltmeter

8.  Wrenches - 1/2", 9/16", 17mm

9.   Drill Bits - 1/4", 5/16", 3/8"

TOOLS REQUIRED

1.  Always wear safety glasses during installation.
2. Keep body and clothing clear of moving parts.

3. No other use of this system is authorized, 

except as designed.

SAFETY INSTRUCTIONS

Содержание AutoGate

Страница 1: ...P N 1128479 Rev A AutoGate Electric Farm Swing Gate Trickle Charge Version ...

Страница 2: ...ement products from our factory to the owner will be paid by us If the product returned is found in our judgement to be non warrantable the owner will be contacted to authorize repair work purchase of a replacement product or return of the product all of which will be at the owner s expense Payment authorization must be received by us before any non warrantable product is repaired replaced or retu...

Страница 3: ...IME Mounting Hardware 1 System Components 2 Stop Plate and Brackets Installation 3 4 Control Box Installation 5 Actuator Installation 6 Trickle Charger Installation 7 Final Adjustments 8 Replacement Parts 9 We at Shur Co are concerned with your safety and the safety of all those operating this system Therefore we have provided safety de cals at various locations on your system Keep decals as clean...

Страница 4: ...072 Hex Head Cap Screw M10 x 1 1 2 1705361 Nylock Hex Nut M10 1700407 Hex Nut 3 8 1700400 Hex Head Self Drilling Screw 3 8 x 1 1704931 Nylock Hex Nut Flange 5 16 1706065 Hex Head Lag Screw 3 8 x 1 1 2 1700428 Flat Washer 5 16 1706066 Hex Head Lag Screw 3 8 x 2 1 2 1700429 Flat Washer 5 16 1706073 Carriage Bolt 3 8 x 7 1703231 Cable Tie 8 1700434 Lock Washer 3 8 1704427 Wire Lock Pin 3 8 x 1 3 4 Q ...

Страница 5: ...9 is long enough to connect trickle charger to control box Routing extension through conduit is recommended Use a weatherproof outlet cover or box to protect trickle charger If livestock can come into contact with gate when fully open or closed gate should be positioned near a sturdy post or fence to prevent damage to bracketry A stop bracket 6 and stop plate 7 are included for closed position if ...

Страница 6: ...g 3 8 carriage bolts F drill 3 8 holes through post If using 3 8 lag screws drill 1 4 holes into post at least 2 1 2 deep E STOP PLATE GATE BRACKET HINGE BRACKET STEP 5 Select appropriately sized U bolts Q R or S for gate crossbar Install gate bracket 5 and 5 16 nuts L but do not tighten nuts at this time Bracket should be able to slide on crossbar STEP 6 Placeinnerslidehingebracket 3 intooutersli...

Страница 7: ... to allow actuator to pivot on hinge bracket Do not place nut at this time Push gate fully open Swing actuator towards gate until actuator points towards gate bracket 5 If actuator body makes contact with gate adjust inner slide hinge bracket 3 out farther by one hole location Alternatively if there is adequate clearance between actuator and gate inner slide hinge bracket may be brought closer to ...

Страница 8: ...r installation STEP 1 Mount control box 1 above hinge bracket Drill holes and install fasteners For wooden posts 3 8 lag screws can be used For metal posts use 3 8 self tapping screws STEP 2 Loosen four 10 fasteners on side holding front panel with 5 16 nut driver Remove front panel STEP 3 Loosentwo 10fastenersonbottomofcontrolboxand remove bottom cover for access to cable connectors Gently pull o...

Страница 9: ... line up with actuator mounting hole Install actuator 4 using cap screws B nylock nuts J and wire lock pin T Tighten nut until snug then back off 1 4 turn STEP 4 Tighten U bolt nuts to secure gate bracket If U bolts cannot be used drill 5 16 holes into gate and fasten gate bracket using 3 8 self tapping screws C u bolt 4 1 4 5 5 4 B J L T C NOTE U bolts may not have enough holding power on some th...

Страница 10: ...n nector ends to be inside control box Make sure trickle charger is not plugged in before cutting extension cable STEP 5 Connect extension cable 9 to control box 1 Red wire from extension cable connects to white wire from control box NOTE Extension cable is rated for direct burial NOTE Check local building codes for requirements STEP 6 Measure battery voltage A fully charged battery should read ab...

Страница 11: ...ear hinge point to allow for gate to open while preventing cable from being pinched by hinge bracket Open and close gate to verify actuator cable has adequate slack and does not become pinched STEP 3 Secure and finalize wiring from trickle charger to control box STEP 4 Gently push connectors and excess wire up into con trol box channel If needed top panel can be removed for better access to wire c...

Страница 12: ... 1 2 15 1127905 Hinge Post Fixed Bracket 16 1700429 Flat Washer 3 8 17 1700434 Lock Washer 3 8 18 1700407 Hex Nut 3 8 Item Part Description 19 1706073 Carriage Bolt 3 8 x 7 For Metal Posts 20 1127908 Hinge Post Slide Bracket 21 1704416 Cap Screw 5 16 x 1 22 1700428 Flat Washer 5 16 23 1700419 Hex Nut 5 16 24 1127655 Linear Actuator 25 1706072 Cap Screw M10 x 35mm 26 1705361 Hex Nut M10 27 1704427 ...

Страница 13: ...P N 1128479 Rev A Notes 10 ...

Страница 14: ...P N 1128479 Rev A Notes 11 ...

Страница 15: ...P N 1128479 Rev A Notes 12 ...

Страница 16: ......

Отзывы: