P/N 1128479 Rev. A
6
Actuator Installation
STEP 1:
Connect actuator
4
cable to control box
1
.
STEP 2:
Use buttons on control box to fully retract actuator.
Extend actuator about 1".
STEP 3:
Ensure gate is in closed position and contacting far
post or stop plate (if installed). Slide gate bracket
5
to line up with actuator mounting hole. Install actuator
4
using cap screws
B
, nylock nuts
J
and wire lock
pin
T
. Tighten nut until snug, then back off 1/4 turn.
STEP 4:
Tighten U-bolt nuts to secure gate bracket. If U-bolts
cannot be used, drill 5/16" holes into gate and fasten
gate bracket using 3/8" self-tapping screws
C
.
u
-
bolt
4
1
4
5
5
4
B
J
L
T
C
NOTE:
U-bolts may not have enough holding power on some
thin-walled tubes. It may be necessary to install self-drilling
screws in addition to U-bolts.