Manual of SR288 intelligent controller
49
1-12
Measuring
range
of
Groudfos
flow
meter(1-12
L/min)
2-40
Measuring
range
of
Groudfos
flow meter
(2-40 L/min)
FRT
OFF
OFF
OFF
/
ON
Rotary vane
flow meter
FLOW
OFF
ON/OFF
Non
flow
warning
DELY
30s
1-600s
1s
Checking
time of non
flow
warning
Function setting
►Select FS menu
►Press “SET”, “GFDS” displays on the screen
►Press “SET”, “VFS OFF” displays
►Press “▲/▼”, to activate this function, “VFS 1-12V” displays on the screen
►Press “▲/▼”, select the range of Groudfos flow meter
►Press “SET” or “ESC” to save the setting
►Press “▲”, “FLOW OFF” displays on the screen
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “FLOW ON” displays
►Press “SET” or “ESC” to save the setting
►Press “▲”, “DELY 30” displays on the screen
►Press “SET”, “30” blinks
►Press “▲/▼”, to adjust the checking time of non-flow warning
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
►Press “▲”, “FRT” displays on the screen
►Press “SET”, “FRT OFF” displays
►Press “SET”, “OFF” blinks