Manual of SR288 intelligent controller
19
3. Both control Modes and temperature control mode, the parameter set steps are same.
Menu structure:
Main
menu
Submen
u 1
Submen
u 2
Factory
set
Adjustabl
e range
Step per
adjust
Description
CIRC
DHW circuit function
TCYC
OFF
ON/OFF
Activate / deactivate the
DHW circuit function
TEMP
OFF
Temperature control
DHW pump
TIME
ON
Time control DHW pump
STAT
ON
ON/OFF
Tank temperature (T3 or
T2) 2
o
C higher than the
preset switch-off DHW
circuit temperature.
CYCO
40
℃
/3min
5-53
℃
/1-30min
0.5
℃
/1min
Switch-on temperature
or running time
CYCF
45
℃
/15min
7-55
℃
/0-60min
0.5
℃
/1min
Switch-off temperature
or stop time
t C1O
05:00
00:00-23:5
9
Switch-on time and
temperature for the first
time section
t C1F
07:00
00:00-23:5
9
Switch-off time and
temperature for the first
time section
t C2O
11:00
00:00-23:5
9
Switch-on time and
temperature for the
second time section