Manual of SR288 intelligent controller
32
Main
menu
Submenu
1
Submenu
2
Submenu
3
Factory
set
Adjustable
range
Step
per
adjus
t
Description
PUMP
Pump control
mode
PMP1(2.)
Selection
pump R1 (R2.)
ONOF
ON
ON/OFF
Pump on/off
(for pump
without speed
adjustment
function)
PULS
OFF
ON/OFF
Pulse control
(Burst control
via
semiconductor
relay
MIN1
30%
20-95%
5%
MAX1
100%
25-100%
5%
PSOL
OFF
ON/OFF
PWM profile
solar pump
MIN1
30%
20-95%
5%
MAX1
100%
25-100%
5%
PHEA
OFF
ON/OFF
PWM profile
heating pump
MIN1
30%
20-95%
5%
MAX1
100%
25-100%
5%
0-10
OFF
ON/OFF
0-10V signal
control pump
speed
MIN1
30%
20-95%
5%
MAX1
100%
25-100%
5%
Function setup
►Select “PUMP” menu
►Press “SET”, “PMP1” displays on the screen
►Press “SET”, “ONOF ON” displays on the screen
►Press “▲/▼”, to select pump type “PLUS
、
PSOL
、
PHEA
、
0-
10V”
►After select pump type, press “SET” to access the pump type.
►Press “SET”, “OFF” blinks on the screen
►Press “▲/▼” to open
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu