background image

 

Ordercode: 43710 

NanoQ 12 Q4 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 

least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 

tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 

the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to 

cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 

engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your device. Leave the 

device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 

(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children. Never leave the unit running 

unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the NanoQ 12 Q4. The manufacturer 

will not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 

conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

  

 

 

   

 

Содержание NanoQ 12 Q4 V1

Страница 1: ...NanoQ 12 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43710 MANUAL ENGLISH...

Страница 2: ...Q 12 Q4s DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 13 1 Auto run mode 13 2 Built in programs 13 3 Manual mo...

Страница 3: ...mperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your lifespan exp...

Страница 4: ...plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the...

Страница 5: ...endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation you...

Страница 6: ...er UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addr...

Страница 7: ...andard DMX controller Onboard LCD display for easy setup Control mode Auto run Built in programs Manual mode Sound controlled Master Slave DMX512 Dimmer 0 100 Strobe 0 20Hz Housing Die cast aluminum p...

Страница 8: ...ng materials from the NanoQ 12 Q4 Check that all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect f...

Страница 9: ...g the end of the electric mains power cord into a proper electric power supply socket 04 When the NanoQ 12 Q4 is not connected with a DMX cable it functions as a stand alone device 05 Please see page...

Страница 10: ...Q 12 Q4 and other devices 05 Link the units as shown in fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second thi...

Страница 11: ...Q4s on a power link 8 fixtures 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct y...

Страница 12: ...e be sure that you do not have any overlapping channels in order to control each NanoQ 12 Q4 correctly If two or more NanoQ 12 Q4s are addressed similarly they will work similarly Controlling After ha...

Страница 13: ...Ordercode 43710 NanoQ 12 Q4 Menu Overview 12...

Страница 14: ...h this menu you can you can set the built in programs 01 Press the MODE button until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to select one of the 10 b...

Страница 15: ...ws press the SETUP button to open the menu 02 Press the UP DOWN buttons to increase decrease the zoom factor The adjustment range is between from OFF to full zoom 3 3 Backlight dimmer settings 01 When...

Страница 16: ...as the master device 7 Settings With this menu you can adjust the device s settings 01 Press the MODE button until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN bu...

Страница 17: ...n to open the submenu 02 Press the UP DOWN buttons to choose either Fast or Smooth dimming mode 8 System information With this menu you can monitor the most important information on the device 01 Pres...

Страница 18: ...nel 6 Zoom 0 255 Zoom from 0 100 10 Channels Channel 1 Dimmer 0 255 From black to brightest Channel 2 Red Dimmer intensity Dimmer must be open 0 255 Red from 0 100 Channel 3 Green Dimmer intensity Dim...

Страница 19: ...mber 67 73 Spring Yellow 74 80 Lime Green 81 87 JAS Green 88 94 Fern Green 95 101 Moss Green 102 108 Primary Green 109 115 Green 116 122 Medium Blue Green 123 129 Light Blue 130 136 Lighter Blue 137 1...

Страница 20: ...10 LEE Colors CH9 must be open 0 10 Backlight dimming function 11 17 Red 18 24 Flame Red 25 31 Deep Golden Amber 32 38 Millenium Gold 39 45 Gold Amber 46 52 Orange 53 59 Chrome Orange 60 66 Deep Ambe...

Страница 21: ...from 0 100 Channel 12 Backlight CH9 must be open and CH10 must be set between 0 10 0 255 Green from 0 100 Channel 13 Backlight CH9 must be open and CH10 must be set between 0 10 0 255 Blue from 0 100...

Страница 22: ...tion spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue Troubleshooting...

Страница 23: ...e disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert te...

Страница 24: ...5 60 Dimmer 0 100 0 100 Strobe 0 20Hz 0 20Hz IP Rating IP20 Housing Specially designed housing ensures an optimum heat dissipation during operation DMX control via standard DMX controller On Board LC...