Do not switch the device on and off in short intervals, as this would reduce the lamp’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).  

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the 
power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use lamps and fuses of same type and rating only. 

 

Allow time to cool down, before replacing lamp.  

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 
 

 

 

 

OPERATING DETERMINATIONS 

 
This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 
 
The minimum distance between light-output and the illuminated surface must be more than 1.3 meter. 
 
The maximum ambient temperature 

t

a

 must never be exceeded. 

 
If this device is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash 
etc. 

 
You endanger your own safety and the safety of others! 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание Genesis Scan CDM-150

Страница 1: ...Genesis Scan CDM 150 ORDERCODE 40020...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...tures and Overview Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Genesis Scan Multiple Genesis Scan DMX Protocol Control Panel Control Mode DMX addressing Stand al...

Страница 4: ...nual modifications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept lia...

Страница 5: ...ure fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If...

Страница 6: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Страница 7: ...coloured glass DMX control via standard DMX controller 7 DMX control channels required Sound controlled via built in microphone Lamp CDM 150 ordercode 80964 80965 80974 80975 Fuse T5A 250V No lamp inc...

Страница 8: ...nstall lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the...

Страница 9: ...light on an even surface wall As the optimal distance between the lamp and the lens was already set during the installation with screw C only the Hot Spot the brightest part of the ray of light must...

Страница 10: ...effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Genesis Scan Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Genes...

Страница 11: ...95 Strobe effect with increasing speed 96 159 Open 160 191 Shutter slow open from left to right with increasing speed 192 223 Shutter slow open from right to left with increasing speed 224 255 Open C...

Страница 12: ...84 Cyan 85 95 Orange 96 105 Magenta 106 116 Blue White Red 117 128 Cyan Magenta Pink Yellow 129 189 Change the colorwheel position step by step clockwise 190 222 Change the colorwheel position step b...

Страница 13: ...s Scan should be 1 7 8 A008 the DMX address of the third Genesis Scan should be 8 7 15 A015 etc Please be sure that you don t have any overlapping channels in order to control each Genesis Scan correc...

Страница 14: ...f the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Functions control panel The control panel is situated on the...

Страница 15: ...No function No function Reset function This option enables the Genesis Scan to index all effects function and return to their standard positions Press until the display shows or If the display shows w...

Страница 16: ...y shows with actually stored address If you want address no playing program don t select No function No function Display reverse With this function you can adjust the display by 180 Press until the di...

Страница 17: ...moke fluid tends to build up residues reducing the light output very quickly The cooling fans dichroic colour filters the gobo wheel the gobos and the internal lenses should be cleaned monthly with a...

Страница 18: ...lamp Replace the old lamp with a new one with the same specifications See page 6 for replacing lamps 3 The fuse Replace the fuse See page 15 for replacing the fuse No Response to DMX Response Suspect...

Страница 19: ...jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a tim...

Страница 20: ...fects Color wheel with variable rotation speed Rotating Gobo wheel 8 gobos 2 glass gobo and 6 metal gobo Colorwheel 8 Single colours 2 Bi colours open DMX control via standard DMX controller Sound con...