background image

 

17 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 

Problem 

Probable cause(s) 

Remedy 

One or more 
fixtures are 
completely dead. 

No power to the fixture 

· Check that power is switched on  
  and cables are plugged in. 

Primary fuse blown. 

· Replace fuse. 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

· Connect controller. 

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

· Install a phase reversing cable  
  between the controller and the first  
  fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

· Check data quality. If much lower  
  than 100 percent, the problem may  
  be a bad data link connection, poor  
  quality or broken cables, missing  
  termination plug, or a defective   
  fixture disturbing the link. 

 
Bad data link connection 

· Inspect connections and cables.  
  Correct poor connections. Repair or  
  replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

· Insert termination plug in output jack  
  of the last fixture on the link. 

Incorrect addressing of the fixtures.  · Check address setting. 
 
 
One of the fixtures is defective and 
disturbs data transmission on the 
link. 

· Bypass one fixture at a time until  
  normal operation is regained: unplug  
  both connectors and connect them  
  directly together. 
· Have the defective fixture serviced   
  By a qualified technician. 

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

· Install a phase-reversing cable  
  between the fixtures or swap pin 2  
  and 3 in the fixture, that behaves  
  erratically. 

Shutter closes 
suddenly 

The color wheel, gobo wheel, or a 
gobo has lost its index position and 
the fixture is resetting the effect. 

· Contact a technician for servicing if  
  the problem persists. 

 
No light 

The power supply settings do not 
match local AC voltage and 
frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

Lamp missing or blown 

· Disconnect fixture and replace lamp. 

 
Lamp cuts out 
intermittently. 

 
Fixture is too hot. 

· Allow fixture to cool. 
· Clean fan. 
· Make sure air vents at control panel  
  and front lens are not blocked. 
· Turn up the air conditioning. 

 

The power supply settings do not 
match local AC voltage and 
frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

Содержание Genesis Scan CDM-150

Страница 1: ...Genesis Scan CDM 150 ORDERCODE 40020...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...tures and Overview Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Genesis Scan Multiple Genesis Scan DMX Protocol Control Panel Control Mode DMX addressing Stand al...

Страница 4: ...nual modifications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept lia...

Страница 5: ...ure fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If...

Страница 6: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Страница 7: ...coloured glass DMX control via standard DMX controller 7 DMX control channels required Sound controlled via built in microphone Lamp CDM 150 ordercode 80964 80965 80974 80975 Fuse T5A 250V No lamp inc...

Страница 8: ...nstall lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the...

Страница 9: ...light on an even surface wall As the optimal distance between the lamp and the lens was already set during the installation with screw C only the Hot Spot the brightest part of the ray of light must...

Страница 10: ...effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Genesis Scan Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Genes...

Страница 11: ...95 Strobe effect with increasing speed 96 159 Open 160 191 Shutter slow open from left to right with increasing speed 192 223 Shutter slow open from right to left with increasing speed 224 255 Open C...

Страница 12: ...84 Cyan 85 95 Orange 96 105 Magenta 106 116 Blue White Red 117 128 Cyan Magenta Pink Yellow 129 189 Change the colorwheel position step by step clockwise 190 222 Change the colorwheel position step b...

Страница 13: ...s Scan should be 1 7 8 A008 the DMX address of the third Genesis Scan should be 8 7 15 A015 etc Please be sure that you don t have any overlapping channels in order to control each Genesis Scan correc...

Страница 14: ...f the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Functions control panel The control panel is situated on the...

Страница 15: ...No function No function Reset function This option enables the Genesis Scan to index all effects function and return to their standard positions Press until the display shows or If the display shows w...

Страница 16: ...y shows with actually stored address If you want address no playing program don t select No function No function Display reverse With this function you can adjust the display by 180 Press until the di...

Страница 17: ...moke fluid tends to build up residues reducing the light output very quickly The cooling fans dichroic colour filters the gobo wheel the gobos and the internal lenses should be cleaned monthly with a...

Страница 18: ...lamp Replace the old lamp with a new one with the same specifications See page 6 for replacing lamps 3 The fuse Replace the fuse See page 15 for replacing the fuse No Response to DMX Response Suspect...

Страница 19: ...jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a tim...

Страница 20: ...fects Color wheel with variable rotation speed Rotating Gobo wheel 8 gobos 2 glass gobo and 6 metal gobo Colorwheel 8 Single colours 2 Bi colours open DMX control via standard DMX controller Sound con...

Страница 21: ......

Отзывы: