11
Control Panel
When the indicator light is on, means the Genesis Scan is working
Fig. 6
A.
LED
D.
[MODE] Button
B.
Display
E.
Up Button
C.
[ENTER] Button
F.
Down Button
Control Mode
The fixtures are individually addressed
on a data-link and connected to the controller.
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it,
the controller will display the saved DMX address the next time.)
DMX Addressing
The control panel on the front side of the base allows you to assign the DMX fixture address, which is the
first channel from which the Genesis Scan will respond to the controller.
Please note when you use the controller, the unit has
7
channels.
When using multiple Genesis Scan’s, make sure you set the DMX addresses right.
Therefore, the DMX address of the first Genesis Scan should be
1(A001)
; the DMX address of the second
Genesis Scan should be
1+7=8 (A008
); the DMX address of the third Genesis Scan should be
8+7=15
(A015)
, etc.
Please, be sure that you don’t have any overlapping channels in order to control each Genesis Scan
correctly. If two or more Genesis Scan’s are addressed similarly, they will work similarly.
For address settings, please refer to the instructions under ”Addressing’ (menu
)
Controlling:
After having addressed all Genesis Scan fixtures, you may now start operating these via your lighting
controller.
Note:
After switching on, the Genesis Scan will automatically detect whether DMX 512 data is received
or not.
If there is
no data received at the DMX-input, the “
LED
“ on the control panel will not flash.
The problem may be:
- The XLR cable from the controller is not connected with the input of the Genesis Scan.
- The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note:
It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.
Содержание Genesis Scan CDM-150
Страница 1: ...Genesis Scan CDM 150 ORDERCODE 40020...
Страница 21: ......