background image

 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact of the (optional) battery charger. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging (plastic bags, polystyrene foam, nails, etc.) within 
children’s reach, as they are potential sources of danger. 

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, 
due to cracks or deep scratches. 

 

If device is dropped or struck, switch off the device. Have a qualified engineer inspect for 
safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), 
do not switch it on immediately. The arising condensation water might damage your device. 
Leave the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Showtec dealer for 
service. 

 

For adult use only. The device must be installed out of the reach of children. Never leave the 
unit running unattended. 

 

The user is responsible for correct positioning and operating of the Eventspot 1900 mkII. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect 
installation of this device. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 
 
 
 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание Eventspot 1900 MKII

Страница 1: ...Eventspot 1900 mkII ORDERCODE 42717 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...ly on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep...

Страница 3: ...control 11 Multiple Eventspots Wireless DMX Control 11 Multiple Eventspots DMX Control 11 Control Panel 13 DMX Control Mode 13 DMX Addressing 13 Menu overview 14 Main Menu Options 16 Creating a static...

Страница 4: ...improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection...

Страница 5: ...y damaged it has to be replaced So that its functions are not impaired due to cracks or deep scratches If device is dropped or struck switch off the device Have a qualified engineer inspect for safety...

Страница 6: ...dequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a...

Страница 7: ...2200 Maximum projection distance 20m Dimmer 0 100 Strobe 0 20Hz Bean angle 16 degrees Battery storage 24Ah Battery run time 12 hours at full RGBA on Battery charging cycle 12 hours Control On board D...

Страница 8: ...11 Auto speed adjustment 12 Dimmer Speed ARC1 Channel Description 1 Red 2 Green 3 Blue ARC1 D Channel Description 1 Master Dimmer 2 Red 3 Green 4 Blue ARC1 S Channel Description 1 Master Dimmer 2 Red...

Страница 9: ...LED 3 Wireless DMX receiver 4 Battery charger socket 5 Height adjustable foot You change the height of this foot to change the operating position of the Eventspot max angle 10 See the next page 6 Pow...

Страница 10: ...d connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging t...

Страница 11: ...port The Eventspot 1900 mkII uses up to 15 channels Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 30 devices should...

Страница 12: ...from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units You can use the same functions on the master device as described on pa...

Страница 13: ...ower supply sockets starting with the first unit Do not supply power before the whole system is set up and connected properly Multiple Eventspots DMX Set Up with individual DMX addressing DMX address...

Страница 14: ...econd Eventspot 1900 mkII should be 1 12 13 the DMX address of the third Eventspot 1900 mkII should be 13 12 25 etc Please be sure that you don t have any overlapping channels in order to control each...

Страница 15: ...14 Menu overview...

Страница 16: ...15...

Страница 17: ...e up E down F buttons you change the static colors Red Green Blue White or the strobe speed 0 20Hz 3 Press the menu C button to go 1 step back You can combine RED GREEN and BLUE to create an infinite...

Страница 18: ...ct the ADDR menu and press the enter D button 2 Use the up E down F buttons to set the DMX address You can choose your DMX address between 001 512 Run Mode 1 Select the RUN menu and press the enter D...

Страница 19: ...device 3 Press the enter D button now the display will show PASS 4 Enter the password by pressing up E down F up E down F 5 Press the enter D button to start uploading While uploading the display wil...

Страница 20: ...ave calibrated the specific color in menu CAL2 RGBW UC RGB output is adjusted to a standard preset universal color This way different versions of Eventspot 1900 mkII s are color balanced to match each...

Страница 21: ...press the enter D button 2 Enter the password by pressing up E down F up E down F enter D 3 Use the up E down F to select the CAL2 menu and press the enter D button 4 Use the up E down F to select RE...

Страница 22: ...o select the key menu Press the enter D button 3 Use the up E down F to switch the Keylock on or off Press the enter D button If no button is pressed for 1 minute the system shuts down and can only be...

Страница 23: ...ors No Function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red 100 Green Up Blue Up Red Down...

Страница 24: ...Channel 8 has priority over channels 2 3 4 5 6 and 7 Channel 1 is used to control the intensity of the COLOR MACRO STROBE CH9 is the strobe channel and controls the strobe effects of CH2 CH3 CH4 CH5 a...

Страница 25: ...Wipe the front glass panel clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front glass panel will require weekly cleaning as smoke fluid tends to build up residues reducin...

Страница 26: ...nnect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on the link i e signal is reversed Install a phase reversing cable between the controller and the first fix...

Страница 27: ...col DMX512 via wireless DMX512 Control Personality Tour Arc1 Arc1 D Arc1 S HSV BLOCK 12CHS 3CHS 4CHS 5CHS 3CHS 6CHS Physical Housing Stainless Steel black anodized IP Rating IP 44 Operation temperatur...

Страница 28: ......

Отзывы: