14
Galactic RGB-6-750
Product code: 51347
Personal Protective Equipment
During installation and rigging wear personal protective equipment in compliance with the national and
site-specific regulations.
Installation Site Requirements
●
The device can be used only indoors.
●
The minimum distance to other objects must be bigger than 0,5 m.
●
The maximum ambient temperature t
a
= 40 °C must never be exceeded.
●
The relative humidity must not exceed 50 % with an ambient temperature of 40 °C.
Rigging
The device can be positioned on a flat surface or mounted to a truss or other rigging structure. Make sure
that all loads are within the pre-determined limits of the supporting structure.
CAUTION
Restrict the access under the work area during rigging and/or derigging.
To mount the device, follow the steps below:
01)
Use quick-lock brackets to attach the device to the supporting structure, as shown in Fig. 08. Make
sure that the device cannot move freely.
02)
Secure the device with a secondary suspension, for example a safety cable. Make sure that the
secondary suspension can hold 10 times the weight of the device. If possible, the secondary
suspension should be attached to a supporting structure independent of the primary suspension. Put
the safety cable through both safety eyes (04), as shown in Fig. 08.
Fig. 08