E N
Nome file:
File name:
7523000 - ISTRUZIONI POOLBUBBLE - 11 LINGUE - A3.doc
Rev. 0 05/04/2011
9 - 28
The
power outlet
must be at a suitable distance from the water but easily accessible in order to be able to easily turn off the product in the event of fault. Cutting the power cord and/or replacing the
power plug
is strictly
prohibited.
The power cord must be positioned to avoid possible damages such as bends and/or cuts.
5.6.1. Filling the air diffuser.
Proceed as follows:
1. Fill the air diffuser (
Fig. 3
, # 10) with sand (not included, about 13.5 [kg]), as illustrated in
Fig. 7
.
2. Submerge the air diffuser under the water surface and drain air.
3. Keeping the diffuser submerged, close with plugs (
Fig. 3
, # 9, 13,
Fig. 7
).
5.6.2. Hose connection.
Proceed as follows:
1. Place the o-ring (
Fig. 3
, # 5) on the
blower
air
outlet
(
Fig. 3
, # 6).
2. Screw in the bayonet adapter (
Fig. 3
, # 4) on the
blower
air
outlet
(
Fig. 3
, # 6).
3. Connect the bayonet connector (
Fig. 3
, # 3) to the air hose (
Fig. 3
, # 1) and secure it with the hose clamp (
Fig. 3
, # 2).
4. Place the air hose (
Fig. 3
, # 1) in the air hose support (
Fig. 3
, # 8) as indicated in
Fig. 7
.
5. Connect the air hose (
Fig. 3
, # 1) to the
check valve
(
Fig. 3
, # 7) and secure it with the hose clamp (
Fig. 3
, # 2), making sure it permits air flow in the correct direction,
Fig. 8
.
6. Connect the air hose (
Fig. 3
, # 14) to the
check valve
(
Fig. 3
, # 7) and secure it with the hose clamp (
Fig. 3
, # 2).
7. Connect the air hose (
Fig. 3
, # 11) to the air diffuser (
Fig. 3
, # 10) and secure it with the hose clamp (
Fig. 3
, # 2), see
Fig. 10
.
8. Position the air hose as indicated in
Fig. 9
.
9. Position the air diffuser inside the
pool
(
Fig. 3
, # 12).
The
check valves
should be placed outside the
pool
and over the water level (
Fig. 2)
.
The air hose (
Fig. 3
, # 11) must pass over the edge of the
pool
.
The
blower
must be raised off the bottom of the
pool
. (by at least 3 [cm],
Fig. 2
).
5.7. Reinstallation and reuse.
In the event of freezing risk, the product must be accurately emptied of all liquid in the air diffuser (
Fig. 3
, # 10).
5.8. Demolition and disposal.
Collecting recyclable material, both those used for packaging (cardboard, nylon, etc.) and those replaced during maintenance is recommended. Suitable collection of waste material for recycling, processing and environmentally
compatible disposal contributes in avoiding possible negative effects on the environment and health and promotes the reuse and/or recycling of product materials.
Illicit product disposal by the user may be punishable by current international and/or national laws.
5.8.1. Electric/electronic waste disposal.
EU directive 2002/96/EC classifies this product as an electrical or electronic tool. The barred bin symbol on the equipment or packaging indicates that the product must be separated from other waste at the end of its working
life. Therefore, the user must take equipment to electronic and electro-technical waste collection centres at the end of its working life or return it to the dealer when purchasing similar new equipment, on a one to one basis.
Suitable collection of decommissioned equipment for recycling, processing and environmentally compatible disposal contributes in avoiding possible negative effects on the environment and health and promote the reuse
and/or recycling of device materials. Illicit product disposal by the user may be punishable by current national laws.
6. Operations and use.
Do not use glue, sealant or other chemical products on threads or other product parts.
6.1. Operating description.
The product you purchased is designed to blow air in the
pool
. With this product your
pool
will become a comfortable
"spa" pool
.
6.2. Application range.
The product was designed and constructed to work with above-ground fresh-water
pools
installed outdoors.
6.3. Use.
Cutting, replacing and/or altering the power cord is strictly prohibited.
The product must only and exclusively be used to blow air in
pools
. It must be used for recreational purposes and installed as illustrated in the user manual.
The product cannot be used for medical/therapeutic purposes,
6.4. Operating limits and environmental limits.
•
Maximum working temperature: +40 [°C].
•
Minimum working temperature: 0 [°C].
•
Maximum water temperature: +40 [°C].
•
Minimum water temperature: +4 [°C].
•
Maximum water height: 1.3 [m].
The product can work continuously for about 20 minutes (time varies according to environmental conditions) until the
thermal protector
triggers. The product resumes operations once the (
blower
) cools.
6.5. Hazards and risks.
The product is an electrical appliance. Therefore, the maximum diligence is required in installation and maintenance to ensure there are no hazards. Pay careful attention to:
•
power cord conditions. It must not be damaged;
•
not leave the product unattended;
•
the product must be stored and used away from the elements;
•
water should never flow towards the
blower
.
•
the
check valves
should be positioned outside the
pool
and above the water level (
Fig. 2
).
7. User instructions.
7.1. Foreseen use and adjustments.
Proceed as follows to use the product:
1. connect the air hose (
Fig. 3
, # 1) to the
blower
using the bayonet connector (
Fig. 3
, # 3)
;
2. plug in the
power plug
in the
power outlet
;
3. enter the water.
When finished using the product:
1. unplug the
power plug
from the
power outlet
;
2. disconnect the air hose (
Fig. 3
, # 1) from the
blower
using the bayonet connector (
Fig. 3
, # 3)
;
3. store the
blower
away from the elements.
8. Routine, scheduled and extraordinary maintenance.
Do not lubricate and/or use detergents and/or chemical products to clean the product.
All extraordinary maintenance (replacing the power cord, etc.) must be performed by specialised technicians.
Before beginning any work, remember to unplug the
power plug
from the
electrical socket.
8.1. Routine maintenance.
Make sure the
blower
vent (
Fig. 3
, # 6) is always free to guarantee correct product ventilation,
Fig. 11
.
8.2. Extraordinary maintenance.
This consists in replacing worn or damaged parts (power cord,
check valve
, etc.).
If the power cord is damaged, it must be replaced by the manufacturer or its technical service centre or by personnel with similar qualifications, to prevent any risks.
9. Troubleshooting.
P
ROBLEM
P
OSSIBLE CAUSE
1
ST SOLUTION
2
ND SOLUTION
No or insufficient power supply.
Check the power supply.
The
power plug
is not correctly inserted in the
power
outlet
.
Firmly insert the
power plug
in the
power outlet.
Air diffuser (
Fig. 3
, # 10) clogged.
Clean the air diffuser (
Fig. 3
, # 10).
The vent is clogged by dirt,
Fig. 11
.
Clean the vent.
Hydraulic components
clogged or bent.
Clean and adjust
hydraulic components
.
Thermal protector
triggered.
Wait until the product (
blower
) cools.
The product does not work.
Air flow against the normal
check valve
direction.
Adjust the
check valves
as indicated in
Fig. 8
.
Contact specialised technicians.
Power cord damaged.
Wear and/or negligence.
Contact specialised technicians.
-
Plastic components damaged.
Wear.
Replace.
Contact specialised technicians.
10. Retail and spare parts and relevant documentation.
See
Tab. 2
with reference to
Fig. 12
.