1.

  Precautions for operating the AccStick 

 

Precautions for operating the AccStick   

Please keep this notice 

Before  using  the  AccStick,  please  read  this  notice  and  the 

AccStick’s  instruction 

manual  thoroughly.  We  will  not  hold  responsibility  of  any  problems  in  relation  to  this 

notice. 

                                           

Problems  resulting  from  the  generation of heat,  etc might  occur  if 

you use misuse the AccStick.

 Note contents as follows. 

 

 

 

 

 

 

 

Any sudden shocks, drops or hard strikes towards the Accstick unit may cause 

body damage or generation of heat with the lithium polymer battery that might 

catch fire. Be careful with this usage.   

           

 

Do not store and operate the AccStick in any place with heats over 60

  or 

extremely wet. These might be cause problems.

 

  Prohibit 

Do not expose AccStick to wet conditions as damage or heating the internal 

battery might be occurred.   

  Prohibit 

           

 

Do not open the casing or modify the AccStick. These might be cause damage or 

other problems. 

  Prohibit 

             

Prevent dust contamination at the connector part of the AccStick to prevent 

damage to the connector and lithium battery from overheating.

 

  Prohibit 

Do not use the AccStick if you have found any errors to the instrument, or swelling 

of the battery. 

Prohibit

 

Always use the cable paired with the AccStick when charge the battery. Other 

cables might cause any problems, overheating or damage to the battery. 

Action

 

When you dispose of the AccStick, please confirm on how to dispose it from a 

scrap company near you. 

Action 

 

 
 
 
 

Danger 

Prohibit 

Содержание A01-16400

Страница 1: ...annot be responsible for any mistakes which might have occurred within its contents Please inform us if you have found obscurities or wrong descriptions skipped descriptions or the like HEAD OFFICE B4...

Страница 2: ......

Страница 3: ...andling of AccStick 3 3 2 2 Data capturing software 4 4 Operation 5 4 1 Battery 5 4 2 Body 6 4 3 Module for data connection charging of battery 6 4 4 Data capacity 7 4 5 Data file 7 5 Steps for instal...

Страница 4: ......

Страница 5: ...k in any place with heats over 60 or extremely wet These might be cause problems Prohibit Do not expose AccStick to wet conditions as damage or heating the internal battery might be occurred Prohibit...

Страница 6: ...hrough the specified software and converted to csv file 2 1 Features 2 1 1 Instrument a 3D MEMS accelerometer 16G 200G b Small size light weight c Built in Timer d Lithium polymer rechargeable battery...

Страница 7: ...his unit in any wet conditions In an environment where the instrument is exposed to the direct sunlight the functions of the electronic circuits and a lithium battery might be severely affected d The...

Страница 8: ...By using the software you are agreeing to the following articles a To use this software Windows 7 10 is necessary as an OS Install the OS onto the hard disc in advance b We are not responsible for any...

Страница 9: ...measuring condition etc Note1 After measuring turn off the main power to prevent any issues with over charging of battery Note2 Measurements should be made during the span of time in which the batter...

Страница 10: ...urn off the power after data has been downloaded to your PC successfully Also retain the power turn off condition after measuring to prevent any issues with over discharge b Connector for connection w...

Страница 11: ...data can be up to a maximum of 500 000 data points with the selected frame length set as 1 frame Refer to table below for the relationship between frame length and number of capture able data Relatio...

Страница 12: ...Stick html Execute setup exe in the folder Click install if a warning screen like the right screen appears Your installation is complete when the screen below appears USB driver install Please install...

Страница 13: ...tween the USB cable module harness and AccStick Install the specific USB driver to your PC Connect AccStick to PC with the cable module like the picture on the right Charge the battery if necessary US...

Страница 14: ...Accstick after data has been downloaded successfully Starting Conditions Select the start date when you select Timer or Timer Acc Then click START Measuring will start automatically at the selected t...

Страница 15: ...f successful Register Upload to the AccStick the measuring conditions you ve selected Letter on the icon change to blue one if successful START Start to measure on the AccStick Time at clicking is sho...

Страница 16: ...ng monitoring function Monitoring data real time can be displayed on the screen after click Monitor while connected between the AccStick and PC To stop the monitoring click Monitor again The vertical...

Страница 17: ...sec Measuring time of 1 frame obtained by Frame Sampling is shown Acc G Measurable acceleration range is selectable from 2 to 400G as you require Sampling ms Sampling for acceleration capturing is se...

Страница 18: ...ing will be stopped after clicking and the time on the PC will appeared Record Data Trig Data Measured acceleration data is shown At Immediately or Timer mode trig data is shown as 1 At Acc or Timer A...

Страница 19: ...fer to P 10 Main power of AccStick was turned off during the measuring Main power should be turned on at the switch on AccStick before starting refer to P 10 After measuring the main power was turned...

Страница 20: ...5ms at 20 Depends on temperature and measuring conditions Operational temperature range 0 to 60 Size mass 32 4 21 0 10 5 15 0g Casing Aluminium 9 1 2 Software Trigger mode 4 modes Immediately Timer Ac...

Страница 21: ...ccur please contact your sales agent or our company We will repair the unit at counter value in the following cases even if it s within the warranty period a Problems due to usage other than normal wo...

Отзывы: