50
0%
50%
100%
(e.g.) Without Feedback potentiometer
Indicates 0% constantly.
0%
50%
100%
(e.g.) 50% of Valve opening
Segments light increasingly to the right in
accordance with the degree of valve opening.
[Bar Graph Indication]
MV, DV or Degree of valve opening is indicated on the bar graph.
Function
Contents
Indication
MV
indication
Scale is -5 to 105%.
Segments light from left
to right in accordance
with the output MV.
DV
indication
In the case of deviation
zero (0), central 2
segments light.
For positive deviation,
segments light
increasingly to the right.
For negative deviation,
segments light
increasingly to the left.
Degree of
valve opening
is indicated.
Scale is 0 to 100%.
Segments light from left
to right in accordance
with the degree of valve
opening.
Without feedback
potentiometer, 0% is
constantly indicated.
(e.g.) Output MV 50%
50%
105%
-5%
Increases to the right in accordance with the output MV.
-
0
+
-
0
+
When deviation unit is set to 1:
(e.g.) Deviation 0 (SV=200, PV=200)
Central 2 segments light.
(e.g.) Negative deviation (SV=200, PV=196)
4 segments of deviation except the central segment light
increasingly to the left in accordance with the deviation.