28(33)
alarm
bit8~bit15 undefined
15
Start/stop control
W
/
0 start up
1 shut
down
/
16
Suction action time
R/W
15
5
127
S
17
Mixing proportion
R/W
0
0
100
%
18
Set the start of mxing
count
cycle
R/W
1
1
9
time
s
19
Filter cleaning cycle
R/W
3
1
99
time
s
20
Suction cycle waiting time
R/W
0
0
9990
10S
21
Filter cleaning set time
before suction
R/W
0
0
99
S
22
Filter cleaning set time
after
suction
R/W
0
0
99
S
23
Discharge check time
R/W
10
5
99
S
24
Shortage count alarm
R/W
3
1
9
time
s
25
Shortage count stop alarm
R/W
3
Shortage
count alarm
99
time
s
26
Standby time after motor
running
R/W
0
0
99
S
27
Buzzer sound type
R/W
1
0
2
/
29
Motor use time record
R/W
0
0
999
10h
30
Full material detection
time
R/W
3
1
9
S
31
Shortage detection time
R/W
3
1
9
S
32
Shut-off time
R/W
0
0
100
S
34
Motor delay stop time
R/W
30
0
999
S
35
Total numbers of mixing
actions
R
0
0
0x03 set
value
time
s
36
Total numbers of cleaning
actions
R
0
0
0x04 set
value
time
s
37
Total numbers of shortage
alarm
R
0
0
99
time
s
38
On/off control
W
0 start up
1 shut
down
/
39
Current action
R
/
/
bit 0 start
0
1
bit 1 standby
0
1
bit 2 filter cleaning
0
1
bit 3 wait for motor stop
0
1
bit 4 suck materials
0
1
bit 5 suck master batch
(mixing)
0
1
bit 6 wait for material
discharge
0
1
bit 7 suction cycle
waiting time
0
1
bit8 ~bit 15 undefined
40
Real-time info.
R
/
/
41
Input and output state
R
/
/
bit 0 shortage input
signal
0 full
material
1 shortage
of
materials