25(33)
F.14
Motor delay stop time
The delay time after [F.01] suction time is over, then the
motor stops running.
30 secs.
0~999 secs.
F.15
Motor using time
Check the motor using time and clear the motor using time.
The method to clear motor using time: set the value to 0, and
press ENT key to clear.
0
(Unit:
10hrs)
0-999
Only 0 can
clear the
time;
4.1.2 Communication Parameter Setting
Press the <MENU> key and <UP> key at the same time for three seconds to
enter the communication parameter setting screen.
Code
Function Description
Parameter
Values
Default
Value
Range
F.30
Communication address
1
1-99
F.31
Communication baud rate
0---19200 1---9600 2---4800
1
0-2
F.32
Parity check
0---invalid 1---odd parity 2---
even parity
0
0-2
4.2 Alarm Program
Description of blender controller, alarm status and solution method
Panel
Code
Alarm Causes
Solution Method
Shortage alarm [F.10]
1. The set suction time is too short.
2. The materials can
’
t be absorbed.
3. Suction pipeline is blocked.
4. Pipeline suction is too small.
1) Add materials
2) Increase suction time
3) Shut down and check the pipe line.
When it sucks the materials again, the alarm
will dismiss or the ENT key on the panel can
also be cancelled or turn on the power again.
Filter warning
Filter screen blocking
1) Shut down and clean the filter screen
or replace filter screen.
The alarm will dismiss when it turns on/off the
power again or it can be cancelled by clicking
the ENT key on the panel.