23(33)
4.1.1 Parameter Setting
Press
Menu key,
and enter parameter setting.
Step 1, Press
“
Up
”
and
“
Down
”
to select parameter, press
“
Set
”
to enter setting
Step 2, press
“
Up
”
and
“
Down
”
to adjust the parameters, press
“
Set
”
for
confirmation and return to up page.
For example: set "suction action time" to 15 secs.
In OFF mode, press the <MENU> key to enter parameter setting.
Press <DOWN> or <UP> key to select the fuction code F.01, and press <SET>
to enter.
Press the <DOWN> or <UP> key to modify the parameter to 15, and press
the<SET> key to confirm the modification.
Code
Description
Parameters
Default
Value
Adjusting
Range
F.01
Suction action time
Motor suction action time whe it short of materials, which is also
the action time of vacuum breaking valve.
Corresponding action: D
15 secs.
5-127 secs.
F.02
Shut-off action time
Start the same time with the suction action, and set the shut-off
time. Set it to 0: not start.
0
0-100 secs.
F.03
Mixing proportion
Start the same time with the suction action, and set the mixing
proportion.
Time calculation method: suction time *[F.03]%
Set it to 0: not start.
0%
not start
0-100%
F.04
Mixing working method
When mixing happens, the layers of mixing action.
For example, if the suction time is 20sec, the mixing proportion
is 10%, and the layer number is 2, then the mixing action is
9s
—
1s ----9s---1s.
Set single layer
’
s working, and the suction time range is 5-99
secs.
Set double layer
’
s working, and the suction time range is 17-99
secs.
Set three layer
’
s working, and the suction time range is 32-99
secs.
Set four layer
’
s working, and the suction time range is 46-99
secs.
If changing the suction time, by calculation, the minimum
suction action of each layer is less than 1 sec., and the program
will force the action changing time to 1 sec.
1
1-4 times