![Shini SAL-430 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/shini/sal-430/sal-430_instruction-manual_1258034024.webp)
24(29)
bit 1 standby
0
1
bit 2 absorbing materials
0
1
bit 3 waiting for material
discharge
0
1
bit 4 clean the filter screen
0
1
bit 5 wait for motor stop
0
1
bit 6 filter blockage alarm
0
1
bit 7 shortage alarm
0
1
bit8~bit15 undefined
15
Startup & shutdown control
W
/
0
startup
1
shutdown
/
16
Suction action time
R/W
15
5
127
S
17
Mixing proportion
R/W
0
0
100
%
18
Circulating startup setting
of mixing action counting
R/W
1
1
9
time
s
19
Filter screen action cycle
R/W
3
1
99
time
s
20
Circulating suction waiting
time
R/W
0
0
9990
10S
21
Screen cleaning setting
time before suction
R/W
0
0
99
S
22
Screen cleaning setting
time after suction
R/W
5
0
99
S
23
Discharge checking time
R/W
10
5
99
S
24
Material shortage counting
alarm
R/W
3
1
9
time
s
25
Material shortage counting
stop alarm
R/W
3
Mat.
shortag
e
countin
g alarm
99
time
s
26
Standby time after motor
running
R/W
20
0
99
S
27
Buzzer alarm type
R/W
1
0
2
/
29
Motor working time record
R/W
0
0
999
10h
30
Full mat. detecting time
R/W
3
1
9
S
31
Mat. shortage detecting
time
R/W
3
1
9
S
32
Mat. shut-off time
R/W
0
0
100
S
34
Motor delay stop time
R/W
0
0
999
S
35
Accumulating times of
mixing actions
R
0
0
0x03
set value
time
s
36
Accumulating times of
screen cleaning actions
R
0
0
0x04 set
value
time
s
37
Accumulating times of
material shortage alarm
R
0
0
99
time
s
38
Startup & shutdown control
W
0
startup
1
shutdown
/
39
Current action
R
/
/
bit 0 startup
0
1
Содержание SAL-430