21(29)
Motor overload alarm
When an overload alarm occurs, it
alarms for shutdown.
1) If the motor is damaged, replace the motor.
2) The setting of thermal overload is wrong,
adjust the setting value again.
Check the cause of motor overload and turn on
the power again;
4.4 Parameter Setting
Press
key and
key together for 3 secs. to enter parameter
setting screen.
Code
Functional Description
Parameters
Preset
value
Range
F.30
Comm. address
1
1-99
F.31
Baud rate
0---19200 1---9600 2---4800
1
0-2
F.32
Odd-even check
0---No test 1---
Odd parity 2--- Even parity
0
0-2
4.5 Operaton Procedure Description
4.5.1 Operation Procedure
Panel Code
Action
Description
Corresponding
Parameter
Parameters
Factory
Setting
Range
R01
Filter screen cleaning
F.06
3 secs.
0-99 secs.
R02
Waiting for motor stop
F.12
3 secs.
0-99 secs.
D
Absoring the materials
(vacuum breaking valve
action)
F.01
15 secs.
5-127 secs.
Absoring masterbatch
material (Close the
vacuum breaking valve
after the action is
stopped)
F.03
0%
0-100%
F.05
3
1-9
次
N01
Waiting time
F.12
3 secs.
0-99 secs.