23(29)
4.6
Communication Address
(
protocol modbus-RTU
)
Address
(keeping
deposit
zone
)
(decimal)
Parameters
Reading R/
Writing W
Default
Parameter
Min.
Value
Max.
Value
Unit
0
Current action
R
/
/
bit 0 shutdown
0
1
bit 1 standby
0
1
bit 2 absorb materials
0
1
bit 3 wait for material
discharge
0
1
bit 4 cleaning the screen
0
1
bit 5 wait for motor stopping
0
1
bit 6 screen blockage alarm
0
1
bit 7 shortage alarm
0
1
Bit 8~bit 16 undefined
1
Real-time info.
R
/
/
3
Suction action time
R/W
15
5
127
S
4
Screen cleaning action
cycle
R/W
10
1
99
次
6
Screen cleaning setting
time
R/W
0
99
S
7
Discharge checking time
R/W
10
5
99
S
8
Standby time after motor
running
R/W
0
0
99
S
9
Screen cleaning setting
time
after suction
R/W
5
0
99
S
10
Waiting time for
circulating suction
R/W
0
0
9990
10S
13
Input and output status
R
/
/
bit 0 shortage input signal
0 full
mat.
1 mat.
shortage
bit 1 filter screen blockage
input signal
0
no
blockag
e
1
blockage
bit 4 suction output
0 no
output
1 output
bit 5 spraying valve output
0 no
output
1 output
bit 6 alarm output
0 no
output
1 output
bit7~bit15 undefined
14
Current action
R
/
/
bit 0 shutdown
0
1