29(51)
Note: in order to prolong the life of honeycomb-rotor, never stop
the machine by cutting down the main power supply directly,
you should turn off the machine by pressing <Button of Switch>
firstly. The later operation ensures honeycomb-rotor
continuously run for a delaying time to cool down the rotor. This
rotating time always is 3 minutes. After the delaying time is
reached, main power supply can be switched off!
Picture 4-5: Start-up and Shutdown Screen
4.1.3 User Menu Screen
Enter Menu Screen by pressing the <Button of function> on Drying Monitoring
Screen or Conveying Monitoring Screen, which has two functional options: time
setting, and multi-language setting.
Picture 4-6: User Meun Screen
4.1.3.1 Timer Setting
Enter into the Timer Screen by pressing the <Time Set> once on Menu screen.
There are two options in this page, Time Set and WSET.