20(51)
2.4 Options
l
Built-in type, which meas that dew-point monitor is installed on the
machine, is convenient to monitor dew-point temperature. Add "D" at
the end of the model code.
l
Portable type, which meas that dew-point monitor is separate from the
machine, is convenient to test dew-point temperature of different
machines. Add "PD" at the end of the model code.
Dew-point Monitor (portable)
l
For models optional with dew-point control, add
“
DC
”
at model behind.
“
ES
”
by setting if dew-point value to control the regeneration required
temperature automatically and lowers power consumption of the
regenerative heater; According to -40OC~+10OC of dew-point value, the
total power consumption can save 0~10%.
l
For models with energy-saving drying management, add
“
ES
”
at model
behind,standard equipped with HMI touch control ,which can save up to
41% of total power consumption. Volume used per hour is settable
between 40~100% as drying capacity to save the totally power
consumption of 35%~0; Standard equipped with heat regenerative
recycler which recycles the regeneration air exhausted heat via plate heat
exchanger and can save 3%~6% of total power consumption.
l
For models optional with drying heat recycler, add
“
HE
”
at model behind.
Dehumidified low temperature air via plate heat exchanger to recycle the
heat of hot-wet return air, which can higher the air temperature in drying
heater and lower the power consumption of the heater, the total power
consumption can save 0%~19%.
l
For models with hopper polished inside, at "P" at the end of the mode
code.
Содержание 4SDD-50U/200H
Страница 1: ...SDD Series Dehumidifying Dryer Date Oct 2018 Version Ver F English...
Страница 2: ......
Страница 41: ...41 51 6 Maintenance and Repair...