37(51)
Return
Air
EGO
Overheat
1. Drying heating closes when alarm rings,
and it is automatically reset after faults are
removed.
2. The part is detected after being electrified,
and error occurs when the return air EGO
overheat input signal proves to be effective
and delays for 2 secs.
Check whether the setting of [regenerative EGO
overheat] and that of
“
normally open
”
and
“
normally close
”
of overheat signal are correct or
not.
Examine the drying blower, regenerative blower,
filter, air pipes and air damper.
After addressing the problem, press the key of
“
reset
”
or reset by re-powering on.
Rotor Error
1. The rotor automatically gets into the state
of
“
timed cooling
”
when alarm rings, and it is
manually reset after faults are removed.
2. Error occurs when the rotor can
’
t be
detected in the [rotor monitoring time] and the
valid time of its input signal exceeds 10 secs.
Set the parameters according to the rotor
conditions: time for the rotor to run a cycle [rotor
monitoring time], and set aside a certain volume.
If you want to disable this alarm, you can set the
parameter [rotor monitoring time] as 0.
After addressing the problem, press the key of
“
reset
”
or reset by re-powering on.
Regenerative Heating
Pipe Disconnection
1. Regenerative heating closes when alarm
rings, and it is manually reset after faults are
removed.
2. The error occurs when the regenerative
heater is turned on and its temp can not reach
the set temp during the period of [regerative
heating error monitoring].
Examine the regenerative heating pipe and its
control circuit as well as heating contactor;
If you do not use the alarm function, you can set
the detection time of disconnection [regerative
heating error monitoring] as 0.
After addressing the problem, press the key of
“
reset
”
or reset by re-powering on.
Drying Heating Pipe
Disconnection
1. Drying heating closes when alarm rings,
and it is manually reset after faults are
removed.
2. The error occurs when the drying heater is
turned on and its temp can not reach the set
temp during the period of [drying heating error
monitoring].
Examine the drying heating pipe and its control
circuit as well as heating contactor;
If you do not use the alarm function, you can set
the detection time of disconnection [drying
heating error monitoring] as 0.
After addressing the problem, press the key of
“
reset
”
or reset by re-powering on.
Regenerative
Probe
Error
1. Regenerative heating closes when alarm
rings, and it is automatically reset after faults
are removed.
2. The part is detected after being electrified,
and error occurs when there is something
wrong with the probe.
Examine the wire and check whether the probe
matches with the controller.
Drying Probe Error
1. Drying heating closes when alarm rings,
and it is automatically reset after faults are
removed.
2. The part is detected after being electrified,
and error occurs when there is something
wrong with the probe.
Examine the wire and check whether the probe
matches with the controller.
Return Air Probe Error
1. Drying heating closes when alarm rings,
and it is automatically reset after faults are
removed.
2. The part is detected after being electrified,
and error occurs when there is something
wrong with the probe.
Examine the wire and check whether the probe
matches with the controller.
Examine the machine and press the key of
“
reset
”
after faults are removed.