- 12 - 

 

When the engine oil pressure drops during operation, the oil pressure monitor lamp 
will flash, and the automatic shutoff will be engaged. 
When this occurs, check the engine oil level, and replenish to the maximum level if 
needed. 

 

<Caution> 

  The engine oil pressure monitor cannot detect the degradation of engine oil itself. 

Please check the engine oil periodically, and change if needed.   
(Refer to

11. Checking and Maintenance

  Check the fuse next, when the abnormality, other than WATER TEMP, BATTERY 

CHARGED OR OIL PRESSURE is detected. If the fuse is burned out, consult 
with our authorized distributor or our engineering section, because there may be 
an abnormality of electric/electronic parts or wiring and repairing may be required. 

 

(4) Overheat Monitor Lamp 

OVERHEAT monitor lamp may flash in the case the machine is used excessively 
over the duty cycle or over load.   
When the OVERHEAT monitor lamp is blinking, this equipment cuts the out put off. 
When this overheat occurs, there may be a possibility of overloading. Always use 
the equipment within the rated duty cycle and output power. 

 

<Caution> 

  There may be a case that the lamp will not flash, depending on the welding type 

or the weather condition. 

 

5-8. Earth Leakage Circuit Breaker and Grounding 

 

        Danger : Electric Shock 

  Ground every grounding terminal to the earth as set out in the manual. 

If even one of all is unconnected by mistake or accident, it will be much more 
dangerous for human body than the NO RELAY case, because leaking current 
inevitably goes through the body. 

  Even though all the terminals of the loads have been grounded to the earth, the 

bonnet (canopy) grounding terminal should be grounded to the earth. 

  Grounding should be made after the engine is stopped. 

  Whenever the earth leakage relay has activated, always repair the leaking 

circuit first. 

 
The equipment is provided with the earth leakage relay in the Circuit Breaker to 
detect any leakage arisen due to the troubles as insulation failure of the load while 
the generator is running. And cutting off the circuit for protection against any 
accident such as electrical shock resulting from the trouble. 

 
The specifications of the earth leakage relay: 

  Rated Sensitive Current: 30mA (or below) 

  (Grounding resistance: 500

Ω

  or below) 

 

(1) Grounding Work 

The qualified electrician should perform the 
grounding work of the following 2 points 
(500

Ω

  or below).

 

  The Outer Bonnet of this equipment (bonnet grounding terminal) 

  The Outer Bonnet of the load 

<Caution> 

  In the event you cannot ground the generator to the earth, consult with the 

authorized distributor or service dealers.

 

 

 

GROUNDING 
ROD 

BONNET   
GROUNDING 
TERMINAL 

Содержание DGW300MS

Страница 1: ...Vertical Water Cooled 4 Cycle Diesel Engine CAUTION Do not operate the Generator Welder or any other appliance before you have read and understood the instructions for use and keep near for readily u...

Страница 2: ......

Страница 3: ...ease attach this manual and explain how to operate and have them read this manual if the equipment will be sub leased Please store this manual near the equipment for easy reference Replace damaged or...

Страница 4: ...6 2 Checking Coolant Water 15 6 3 Checking Fuel 15 6 4 Checking Fuel Engine Oil and Water Leakage 16 6 5 Checking Battery 16 7 Operation the Engine 17 7 1 Starting 17 7 2 Stopping 18 7 3 Emergency Sto...

Страница 5: ...ing the maintenance should always keep the key Danger Electromagnetic Interference Person with a pacemaker of the heart do not approach the equipment and welding around the work site during work May a...

Страница 6: ...the engine and muffler during operation and immediately after stopping the equipment for the temperature could reach extremely high When checking engine oil or changing oil always stop the engine and...

Страница 7: ...he following figure When ordering the new label use the following part numbers Suffocation from exhaust fume No X505 004900 Suffocation from welding fume No X505 004910 Electric shock No X505 004930 F...

Страница 8: ...CD or Higher Lubrication Oil Volume L 3 8 Effective 1 4 Cooling Water Volume L 3 0 Sub Tank Capacity 0 6 L included Engine Starting Method Starter Motor Battery 46B24L Japan Industrial Standard Fuel...

Страница 9: ...WITCH WELD TERMINAL SWITCH WIRE FEEDER VOLT METER SWITCH 42V 115V SELECTOR SWITCH CIRCUIT PROTECTOR FOR WIRE FEEDER FUEL METER STARTER SWITCH AC METER DC METER OPERATION MODE SELECTOR SWITCH EMERGENCY...

Страница 10: ...PLUG WATER DRAIN PLUG RIGHT DOOR AIR CLEANER BATTERY FUSE 60A 10A FUEL LEVER FUEL STRAINER SUB TANK OIL GAUGE 1 P RECEPTACLE EARTH LEAKAGE CIRCUIT BREAKER ELCB 1 P BREAKER BONNET GROUNDING TERMINAL FO...

Страница 11: ...racteristic feature Connecting a wire feeder and then turning the CC CV Selector Switch to CV WIRE semi automatic welding such as MIG MAG SS etc is available to perform Connecting the welding cables a...

Страница 12: ...on at AT OR ABOVE 35V side the welding voltage is exceeded more than 35V or while the VRD Selector switch is at TEST mode 5 4 Output Remote Control The equipment incorporates Optional Output Remote Co...

Страница 13: ...ELDER Both Welder and Generator mode WELDER ONLY Only welding function mode GEN ONLY Only generating function mode 5 6 Meter The equipment incorporates digital meters voltage amperage of welding outpu...

Страница 14: ...erature rises abnormally the coolant water temperature monitor lamp will flash and the automatic shutoff will be engaged When this occurs check the coolant water reservoir tank and replenish if needed...

Страница 15: ...Leakage Circuit Breaker and Grounding Danger Electric Shock Ground every grounding terminal to the earth as set out in the manual If even one of all is unconnected by mistake or accident it will be m...

Страница 16: ...ition in between ON and OFF In the case stop the engine promptly and find the leakage point to repair After repairing leakage point s reset the ELCB by following procedure Push the ELCB lever down to...

Страница 17: ...unintentional touching cooling fan and fan belt Caution Fire Burns Injuries When checking engine always stop the engine and keep away from fire Wait until the engine cools down before performing any i...

Страница 18: ...prevent freeze and rust 30 mixture LLC is filled when shipped from factory Mixture ratio of the coolant should be 30 45 depending on the ambient temperature Replace LLC at every year or 2000 hours Mi...

Страница 19: ...ur physician immediately Caution Explosion Do not use the equipment or charge the battery in the case the battery fluid level is lower than the LOWER level Battery may emit some combustible gas so kee...

Страница 20: ...on Check to see if it is safe around the equipment before starting When operating the equipment by two or more persons ensure all work condition are safe Do not use the equipment on dusty hot and humi...

Страница 21: ...t 5 minutes Turn the Starter Switch to STOP After the engine has stopped turn the every Fuel Lever to CLOSE Turn the Battery Isolator Switch to OFF position Caution When the engine does not stop in sp...

Страница 22: ...38 8 2 Polarity There are two welding output terminals and Select the polarity according to the operation referring to the table below Caution Follow the instruction of the welding rods the polarity o...

Страница 23: ...uty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minutes period Caution The equipment may be damaged due to overheat if welding more than duty cycle 8 5 Welding Danger Electroma...

Страница 24: ...sing 14 Pin Connector Turn the Weld Terminals Switch to WELD TERMINALS ON Turn the CV CC Selector Switch to CV WIRE Set the voltage by the Output Control Dial While using 14 Pin Connector Turn the 42V...

Страница 25: ...ng the maintenance should always keep the key Ground the every grounding terminal to the earth as set out in the manual If even one of all is unconnected by mistake or accident it will be much more da...

Страница 26: ...h Leakage Relay When any breaker has tripped restore the circuit breaker as per the following procedure Turn OFF all the power switches in the loads Turn push up the breaker to ON Caution Take care fo...

Страница 27: ...in the case the battery fluid level is lower than the LOWER level Battery may emit some combustible gas so keep it away from fire and sparks To optimize the use of this generator welder we recommend t...

Страница 28: ...16 Adjust Tension V Belt 1st 2 nd or after 17 Change V Belt or 2 years 18 Clean Radiator Fin 19 Clean Radiator inside 20 Change Fuel Hose Oil Hose Vibration Absorbing Rubber or 2 years 21 Adjust Engi...

Страница 29: ...ter wrench Supply oil and install the filler cap Caution If an oil filter wrench is not available contact our authorized distributor or service dealers Oil Filter Part No 15241 32090 Kubota 3 Clean Ch...

Страница 30: ...crew the retainer ring counterclockwise and remove the cup and the gauze filter Dispose water or dirt inside the cup When dirt is adhered to the gauze filter clean the filter by compressed air Reassem...

Страница 31: ...g this equipment to avoid injuries by unintentional touching cooling fan and fan belt Caution Injuries Before performing any equipment check or maintenance stop the engine and remove the engine key A...

Страница 32: ...oms Possible Cause Corrective Actions Starter motor does not start 1 Battery Isolator Lever is OFF position 2 Weak Battery 3 Dead Battery 1 Turn Battery Isolator Lever to ON position 2 Recharge Batter...

Страница 33: ...is selected for CC Mode 1 Turn the dial counterclockwise 2 Turn the dial counterclockwise to negative side 3 Turn to CV mode Unable to weld the Cellulose rods 1 OTHERS mode is selected for rod selecti...

Страница 34: ...osed door and or intake exhaust clogging etc E03 Welding output Short Circuit Shut off the engine immediately and confirm if there is short circuit on the welding output Start the engine after resolvi...

Страница 35: ...32 14 Engine Wiring Diagram...

Страница 36: ...33 15 Generator Wiring Diagram...

Страница 37: ...34 MEMO MEMO MEMO MEMO...

Страница 38: ...35 MEMO MEMO MEMO MEMO...

Страница 39: ...36...

Страница 40: ...37 2011...

Отзывы: