- 20 -
•
The load incorporated in motor may require bigger power than the rated power
consumption. Therefore, consult with authorized distributor to clarify.
•
When connecting to use 2 or more sets, start the load one by one, not to start them
simultaneously.
•
When switching a Mercury bulb ON again, wait for approximately 15 minutes until
the bulb cools down.
9-3
.
.
.
.
Operation
Danger : Electric Shock
•
Before connecting or disconnecting a plug from output receptacle, always
turn the circuit breaker to OFF position.
Caution : Injuries
•
Be sure to insert a plug to a receptacle, after confirming that all the
switches in the loads are positioned to
『
OFF
』
.
•
Be sure to select the correct frequency, designated in the loads.
Caution : Damage to the property
・
・
・
・
Aftermath
•
Whenever connecting to use medical equipment or appliances, be sure to
consult with the medical equipment company, doctor or hospital personnel.
•
Be sure to select the correct frequency, designated in the loads. Otherwise
the loads may be damaged.
< Caution >
•
During operation, AC voltage meter always displays the voltage in 200/220V AC
output both at the breaker position
『
ON
』
and
『
OFF
』
.
①
Select the correct frequency, designated in the loads.
(
Refer to
『
5-5
.
Frequency Change
』
)
②
Turn the power switch to
『
OFF
』
in the load.
③
Start the engine.
(
Refer to
『
7-1
.
Starting
』
)
④
Check the frequency by monitor lamp.
⑤
Turn the breaker to
『
OFF
』
.
⑥
Connect the load to the output receptacles.
⑦
Turn the breaker to
『
ON
』
.
■
The Circuit breaker has activated due to overload
Caution: Injuries
•
Be sure to turn the power switch off in the load when turning the circuit
breaker to
『
ON
』
again, when the circuit breaker has activated.
MONITOR LAMP
BREAKER
RECEPTACLE