- 24 -
10. Simultaneous Use of Welding and Generating
The circuit breaker reacts on the AC power supply circuit only. In the simultaneous use of
welding and generating, overload to the engine may occur.
Refer to the following table for simultaneous use of welding and generating
Welding Output
AC Power Output
Welding Rod / Current
50Hz
60Hz
2.0mm/60A
3.0kVA or below
3.3kVA or below
2.6mm/100A
2.5kVA or below
3.0kVA or below
3.2mm/140A
1.0kVA or below
1.5kVA or below
4.0mm/170A
0.5kVA or below
0.5kVA or below
11. Checking and Maintenance
Danger : Electric Shock
・
・
・
・
Injuries
Before performing any equipment check or maintenance, stop the engine, and
remove engine key. The person performing the maintenance should always
keep the key.
Danger: Burns
Do not open the radiator cap while operating this equipment or immediately
after stopping the equipment, to avoid sustaining burns from hot water/steam.
Caution: Fire
・
・
・
・
Burns
Keep the equipment away from fire.
When checking engine, always stop the engine. Wait until the engine cools
down, before performing any checks.
Do not touch the engine or muffler immediately after stopping the equipment,
Wait until the engine cools down, before performing any checks.
Caution: Injuries to eyes and skin
Battery fluid contains diluted sulphuric acid. Avoid contact with eyes, skin or
clothing. If the acid comes in contact, especially with eyes, flush with lots of
water, and seek medical attention.
Caution: Explosion
When the liquid level is below the LOWER level, do not use the equipment or
recharge the battery.
Battery may emit combustible gases. Keep it away from fire and sparks.
Caution: Fire
Battery may emit combustible gases, Keep it away from fire and sparks.