15
Remote Start
Terminal
(2) Pilot Lamp
This lamp illuminates when the engine is operating to indicate that power is being generated.
(3) Over Crank Indicator/No Speed Signal
This indicator lights up if the engine fails to start.
If that happens, set the starter switch selector
to "STOP," and inspect the machine.
(Refer to section "12. Troubleshooting.")
If the LED light starts flashing, the rotation signal has
not been detected correctly.
In that case, contact the authorized distributor where
the generator was purchased
.
Switches
(1) Starter Switch
The engine warms up and starts automatically.
START
The engine starts automatically.
STOP
The engine is stopped, and the power
supply is turned off completely in this
position. You can also operate the
accessory switch in this position.
AUTO
The engine is started in this position
when the remote start terminal closes.
(2) Accessory Switch
If you select "ON," the display turns on, and you can check the fuel gauge.
< Note >
Set the starter switch selector to "STOP" to activate this function.
Do not leave the accessory switch in the "ON" position. This is to prevent the battery from drain
out.
(3) Breaker
This switch is for transmitting electrical power to the load side. Turn to ON position to output
voltage to the output receptacles. Output to the load side is cut off when there is a short circuit
or overload on the load side.
< Note >
Do not turn off/on the breaker manually to operate or stop a load.
Starter Switch
Pre-Heating
Indicator
1-Phase
Breaker
Accessory Switch
OVER CRANK INDICATOR
Содержание DGK7F
Страница 2: ......
Страница 46: ...43 13 Generator Circuit Diagram...
Страница 47: ...44 14 Engine Electrical Circuit Diagram...
Страница 48: ...2018...