18
5-7. Fuel Piping Switch (3Way Fuel Valve)
Change the three-way fuel valve to switch to supply
fuel from the external tank. In that case, the internal
fuel tank will not be used.
(1) If using the internal fuel tank
Change the lever of the three-way fuel valve turned to
the “B” side to supply fuel from the internal tank. It is
turned to the “B” side when the generator is shipped
from the factory.
< Note >
When disconnecting piping from the external tank,
turn the lever to the “B” side, and attach the bundled
plug (R1/2”) to the external tank fuel inlet/return.
(2) If using an external fuel tank
Connect hoses from the external fuel tank
to the external fuel inlet and the external
fuel return.
Change the lever of the 3way fuel valve to
the “A” side to supply fuel from the
external tank.
Refer to “
9-6. Connecting with External
Fuel Tank
” for corresponding procedures.
6-1. Transport Procedures
CAUTION : FIRE
Always make sure that the engine is stopped when working on piping.
Always be sure to wipe up any spilled fuel.
After working on the piping, check that there is no fuel leakage.
WARNING : INJURY
Always be sure to use “Lifting Hook” when lifting up the generator. Using other parts
when lifting up the generator could cause the result of falling.
No persons should ever be under a lifted generator.
CAUTION : INJURY
Always be sure to use “Lifting Hook” when lifting up the generator, and lift slowly
and vertically.
Personnel performing lifting work must wear protective gear such as helmets, safety
shoes and gloves.
Do not move the generator during operation.
6. Transport/Installation
3Way Fuel
Valve
External
Fuel Inlet
External
Fuel Return
Position B
Position A
Return Side
Inlet Side
Return Side
Inlet Side
Содержание DGK15FL
Страница 2: ......
Страница 51: ...48 13 Generator Circuit Diagram ...
Страница 52: ...49 14 Engine Electrical Circuit Diagram ...
Страница 53: ......
Страница 54: ... 2020 ...