Shindaiwa DGK11F Скачать руководство пользователя страница 26

 

23 

 

 

No 

Nomenclature 

Part to 

be 

tighten 

Size 

Qty 

Torque 

Allowance 

Nm(kg

f/

cm) 

Reference 

24 

Lead ~ Circuit 

Protector (50A) 

Screw 

M6x12 

2.5-4.0 

26-40 

Screws are attached. 

25 

Lead ~ Circuit 

Protector (30A) 

Screw 

M6x12 

2.5-4.0 

26-40 

Ditto 

26 

Lead ~ Circuit 

Protector (30A) 

Screw 

M6x12 

2.5-4.0 

26-40 

Ditto 

27 

Lead ~ Circuit 

Protector (20A) 

Screw 

M6x12 

2.5-4.0 

26-40 

Ditto 

28 

Pilot Lamp ~ 

Operational Panel 

Put an adhesive. (TB 
PANDO) 

Note: Refer to the following “General Tightening Torque” for the general torques that are not specified 

  above. 

 

7-2 General Tightening Torque

                                                                      Unit: 

N

m {kgf

cm}

 

 

Intensity 

4.6, 4.8, 5.6, 5.8, 6.3 (4T, 5T, 6T) 

8.8, 9.8, 10.9, 12.9 (7T) 

Nominal 

Designation 

Nominal 

Tightening Torque 

Allowance Limit 

Tightening 

Strength 

N{kgf} 

Nominal 

Tightening Torque 

Allowance Limit 

Tightening 

Strength 

N{kgf} 

3 × 0.5 

0.6 

{6} 

0.5 

  0.8 

{5 

  8} 

845 

{86} 

1.2 

{12} 

1.0 

  1.5 

{11 

  15} 

1610 

{164} 

4 × 0.7 

1.5 

{15} 

1.3 

  1.9 

{14 

  19} 

1475 

{150} 

2.8 

{29} 

2.8 

  4.8 

{29 

  49} 

2810 

{287} 

5 × 0.8 

3.0 

{30} 

2.6 

  3.8 

{27 

  39} 

2386 

{243} 

5.7 

{58} 

4.8 

  7.1 

{49 

  72} 

4544 

{463} 

6 × 1.0 

5.1 

{52} 

4.3 

  6.4 

{44 

  65} 

3377 

{344} 

9.6 

{98} 

8.6 

  14.4 

{88 

  147} 

6432 

{656} 

8 × 1.25 

12 

{125} 

11 

  16 

{112 

  163} 

6149 

{627} 

23 

{239} 

20 

  30 

{204 

  306} 

11712 

{1194} 

10 × 1.5 

24 

{248} 

21 

  31 

{214 

  316} 

9744 

{994} 

46 

{473} 

40 

  60 

{408 

  612} 

18560 

{1893} 

12 × 1.75 

42 

{433} 

37 

  54 

{377 

  551} 

14162 

{1444} 

81 

{825} 

70 

  100 

{714 

  1020} 

26976 

{2751} 

14 × 2.0 

68 

{690} 

60 

  85 

{612 

  867} 

19320 

{1970} 

129 

{1313} 

110 

  160 

{1122 

  1632} 

36800 

{3753} 

16 × 2.0 

106 

{1076} 

90 

  130 

{918 

  1326} 

26376 

{2690} 

201 

{2049} 

170 

  250 

{1734 

  2549} 

50240 

{5123} 

18 × 2.5 

145 

{1480} 

125 

  180 

{1275 

  1835} 

32256 

{3289} 

276 

{2819} 

235 

  345 

{2396 

  3518} 

61440 

{6265} 

20 × 2.5 

206 

{2099} 

175 

  260 

{1785 

  2651} 

41160 

{4197} 

392 

{3997} 

335 

  490 

{3416 

  4997} 

78400 

{7995} 

22 × 2.5 

280 

{2855} 

240 

  350 

{2447 

  3569} 

50904 

{5191} 

533 

{5438} 

455 

  665 

{4640 

  6781} 

96960 

{9887} 

24 × 3.0 

356 

{3628} 

305 

  445 

{3110 

  4538} 

59304 

{6047} 

678 

{6911} 

575 

  845 

{5863 

  8617} 

112960 

{11519} 

Material 

SS, S××C, SWRM, SWCH 

NC, SNCM, SCM (hardening & tempering treated) 

Содержание DGK11F

Страница 1: ...ourself with its contents for your safety This equipment should only be operated and maintained by trained and qualified personnel This equipment is designed for generating power source of electric to...

Страница 2: ...information contained in this service manual describes equipment available at the time of publication While every attempt has been made to give you the very latest information about your product there...

Страница 3: ...mension 5 5 General Parts Description 7 5 1 Equipment 7 5 2 Main Parts and Feature 10 5 3 Main Component 10 6 Service Data 14 6 1 Service Data 14 6 2 Generator 15 7 Tightening Torque 22 7 1 Specific T...

Страница 4: ...service and maintenance of the equipment for understanding of the equipment safety instructions and cautions Throughout this manual are special attention statements A statement preceded by the triangu...

Страница 5: ...nt is used in poorly ventilated area such as inside of the building Entangled Injuries under By Moving Component NEVER reach and touch the moving component during operation ALWAYS stop the engine duri...

Страница 6: ...e Before replacing the label s make sure to place the new label s in the same position STOP the equipment immediately when abnormal circumstances are noticed STSTOP the equipment immediately whenever...

Страница 7: ...Output hp 19 5 Rated Speed rpm 1800 Displacement cu in liters 91 5 1 499 Combustion System Indirect Injection Cooling Method Radiator Lubricating Method Forced Lubrication Starting Method Electric Fu...

Страница 8: ...5 4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm...

Страница 9: ...6 EXHAUST GAS OUTLET WATER OUTLET...

Страница 10: ...7 5 General Parts Description 5 1 Equipment...

Страница 11: ...8...

Страница 12: ...9...

Страница 13: ...pment is malfunctioned Volt Meter Selector Dial Feature Dial to change voltage Idle Control Switch Feature Switch to set the engine speed idle when electric supply is not performed to reduce noise and...

Страница 14: ...rom the top cover Fuel Return Feature Outlet to return fuel from the external tank Spill Containment Drain Plug Feature Drain a liquid from the spill containment Refer to page 36 in the operator s man...

Страница 15: ...n fuel tank Position the 3 way valve lever to LEFT to use fuel from the external fuel tank Position B to use an external fuel tank Position the 3 way valve lever to RIGHT to use fuel from a built in f...

Страница 16: ...13 Left Side Door Standard Accessory Owners Manual 1 copy Engine Warranty Manual 1 copy Starter Key 1 set 2 pcs...

Страница 17: ...n 1 Max rpm at no load 60Hz 1800min 1 Lubricant oil pressure 0 24 0 44MPa 2 5 4 5kgf cm Coolant temperature 70 95 158 203 F Frame temperature limit within 80 176 F Sealed bearing temperature limit wit...

Страница 18: ...15 6 2 Generator Stator Rotor Rotor Exciter field Main bearing Exciter armature Main stator Fan cover Armature Thermo label Rear bracket Bolt Exciter stator Thermo label...

Страница 19: ...F 220 of the ambient temperature The resistance must be measured by low resistance tester It can not be measured by multi purpose tester cause of index error Main Stator Exciter Stator Rotor 1 2 3 4 5...

Страница 20: ...17 4 Excitation Winding Main Stator Remove the wire harness from the AVR and measure the resistance among A B B C and C A by the low ohm tester Each shall be 0 97 C Or B Y A Br AVR...

Страница 21: ...the J K by the low ohm tester It shall be 23 2 K Vi J Gr Remove the varnish by a sand paper and measure Exciter Field the resistance among the two points as shown in the photo above by the low ohm tes...

Страница 22: ...Method Condition to verify Criterion Monitor Glow Monitor Lamp Hour Meter Visual Inspection After starter switch RUN position 1 Engine is not running Monitor for engine displays 8888 and 8 8 is displa...

Страница 23: ...e Dynamo AC Voltage Meter Voltage 240 1V 50A receptacle rated X Y Frequency 60 0 1Hz Receptacle Output 30A 240V 240 1V Receptacle Output 30A 120V 120 1V Receptacle Output GFCI 120 1V 1 Phase Output Lo...

Страница 24: ...3 6 12 12 6 Mode Output Voltage V Setting Time Frequency Hz Setting Time Loaded No Load Transient Max below 288 below 2 sec below 66 below 8 sec No Load 240 3 60 0 1 No Load Loaded Transient Min over...

Страница 25: ...nel Front Door Nut 5 M5 2 2 0 2 9 21 29 11 Drain Plug Socket Drain Plug M12x1 25x13 1 39 3 49 0 401 499 Insert the packing 12 Fuel Pump Bonnet Stay Attention to the direction for installation of the f...

Страница 26: ...45 86 1 2 12 1 0 1 5 11 15 1610 164 4 0 7 1 5 15 1 3 1 9 14 19 1475 150 2 8 29 2 8 4 8 29 49 2810 287 5 0 8 3 0 30 2 6 3 8 27 39 2386 243 5 7 58 4 8 7 1 49 72 4544 463 6 1 0 5 1 52 4 3 6 4 44 65 3377...

Страница 27: ...water and sediments Drain Fuel filter Clean and Replace Clean Replace Fuel Tank Drain water Water Separator and Gauze Filter Clean Fuel Tank Clean Check Leaks Fuel Oil Coolant Fuel Cooling Water Oil H...

Страница 28: ...er in water sedimenter fuel filter or fuel tank 5 Extract the air 6 Check piping connection 7 Check lever 3 way valve 8 1 Check Change fuse 8 2 Check Change fuel cut solenoid 9 Contact your distributo...

Страница 29: ...does not goes up to the rated voltage 1 Voltage meter is defective 2 AVR is defective 3 Voltage regulator dial is defective 4 Frequency is low 5 Improper load cable connection 6 Voltage selector switc...

Страница 30: ...10 Wiring Diagram 27...