![Shindaiwa DGK11F Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/shindaiwa/dgk11f/dgk11f_service-manual_1257632019.webp)
16
(1) Exciting Amperage
Amperage fluctuates based upon the winding temperature. Following is for reference only.
Frequency/Rated Output
Load
Exciting Amperage (Measured)
3-Phase
60Hz: 11kVA
No load
0.38A
Full load( power factor=1.0)
0.63A
(2) Resistance Value
Nominal resistance of the winding is tolerated
within
± 10% at 32
°
F(
220
℃
) of the ambient
temperature.The resistance must be measured by low resistance tester. It can not be measured
by multi-purpose tester cause of index error.
Main Stator
Exciter Stator
Rotor
1
2
3
4
5
Armature
Exciter Winding
J
-
K
Exciter Field
Armature
U-W
A – B
B – C
C – A
-
-
0.25
Ω
0.97
Ω
23.2
Ω
11.0
Ω
2.7
Ω
[Color Code]
(B)
(W)
(R)
(G)
(Y)
(Br)
(L)
(Or)
(Gr)
(Vi)
Black
White
Red
Green Yellow Brown Blue Orange
Gray Vioret
(3) Armature (Main
Stator)
Low resistance tester
Measure the resistance among the U~W by the low ohm tester. Each shall be 0.25Ω.
U
W
Содержание DGK11F
Страница 8: ...5 4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm...
Страница 9: ...6 EXHAUST GAS OUTLET WATER OUTLET...
Страница 10: ...7 5 General Parts Description 5 1 Equipment...
Страница 11: ...8...
Страница 12: ...9...
Страница 16: ...13 Left Side Door Standard Accessory Owners Manual 1 copy Engine Warranty Manual 1 copy Starter Key 1 set 2 pcs...
Страница 30: ...10 Wiring Diagram 27...
Страница 31: ...28...