![Shindaiwa DGK11F Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/shindaiwa/dgk11f/dgk11f_service-manual_1257632023.webp)
20
Over Speed
Ground over speed terminal
with a unit. Operate at high rpm
in 50 Hz and switch to 60Hz.
Engine stops during 1500min
-1
and
1800min
-1
and OVER SPEED lamp ON.
O
p
e
ra
ti
o
n
a
l
C
h
e
c
k
AVR Adjustment
AC Voltage
Meter
No Load
Voltage Adj. Dial: Max.
Set VRD volume in AVR
at center-position.
(#4)
Adjust by
Frequency
(Hz)
Output
(V)
VRF
(#4
)
50
±
0.1
226±2
VRE
(#4)
60
±
0.1
255±2
Fuel Volume
Visual
Inspection
No Load
Frequency: 60
±
0.1 Hz
Throttle Switch
kVA
Idle
0.0
U-W/U-N/W-N
Run
11/2.4/3.6
U-W/U-N/W-N
1-Phase Output
Load Tester
Frequency
Meter
Dynamo
DC Current
Meter
Output: 240±1V (50A
receptacle, rated, X-Y)
Frequency: 60±0.1Hz
Power Factor: 1.0
Water Temp: 32~212
°
F
(0~100
℃
)
%
kW
V
A
RPM
100
11±0.1
240±1
(0.65)
1800±
10
75
8.3±0.1
240±3
50
5.5±0.1
25
2.8±0.1
0
no load
(0.37)
1-Phase Output
(Receptacle)
Dynamo
AC Voltage
Meter
Voltage: 240±1V (50A
receptacle, rated, X-Y)
Frequency: 60±0.1Hz
Receptacle Output (30A/240V)
240±1V
Receptacle Output (30A/120V)
120±1V
Receptacle Output (GFCI)
120±1V
1-Phase Output
Load Tester
Dynamo
Voltage: 240V (50A Receptacle,
X-Y)
Load: 40±1A (50A Receptacle, X-Y)
Frequency: 60±0.1Hz
Output
(kVA)
U-V
1.4±0.2
Current Transformer
and Analog Current
Meter Wiring
Load Tester
Dynamo
Voltage: 240±1V (50A
receptacle, rated, X-Y)
Frequency: 60±0.1Hz
Power Factor: 1
#5
1-Phase Output
(Transient Load
Change Excursions)
Load Tester
Frequency
Meter
Dynamo
Stop Watch
50A Receptacle (X-Y)
Output: 11.0±0.1kW
Voltage: 240±1V
Frequency: 60±0.1Hz
Power Factor: 1
#6
Voltage Adjustment
AC Meter
Adjust the voltage
regulator
Frequency: 60±0.1Hz
Max. Voltage
Min. Voltage
Over 252
Below 204
#1: When coolant temp is around at 0~50
℃
. (32~122°F)
#2: Spill Containment Sensor
#3: Oil pressure is displayed in a range between 35~57psi.
#4: AVR Adjustment
Float Sensor
Feature: detect the level of liquid
in a tank.
Содержание DGK11F
Страница 8: ...5 4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm...
Страница 9: ...6 EXHAUST GAS OUTLET WATER OUTLET...
Страница 10: ...7 5 General Parts Description 5 1 Equipment...
Страница 11: ...8...
Страница 12: ...9...
Страница 16: ...13 Left Side Door Standard Accessory Owners Manual 1 copy Engine Warranty Manual 1 copy Starter Key 1 set 2 pcs...
Страница 30: ...10 Wiring Diagram 27...
Страница 31: ...28...