21
#5:
Load
Receptacle
Avail. Output (kVA)
Analog Current
Meter (A)
U-W
U-N
W-N
U
W
Simultaneous
50A (X-Y)
15.0±1A
4.5
1.7
2.2
(21)
(27)
30A/120V
100V/1kW
GFCI
100V/500W
Single
30A/120V
100V/500W
8.1
2.4
3.6
(12)
(12)
#6:
Mode
Output Voltage (V)
Setting Time
Frequency (Hz)
Setting Time
Loaded
No Load
(Transient Max.)
below 288
below 2 sec.
below 66
below 8 sec.
No Load
240±3
-
60±0.1
-
No Load
Loaded
(Transient Min.)
over 192
below 2 sec.
over 54
below 8 sec.
Loaded
240±3
-
60±0.1
-
Set the VRD volume in the
center-position before adjustment
Put the adhesive (ThreeBond #1401C)
over the VRF, VRD and VRE after
adjusted.