![Shindaiwa DGK11F Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/shindaiwa/dgk11f/dgk11f_service-manual_1257632022.webp)
19
(7) Technical Specifications
It
e
ms
Article
Method
Condition to verify
Criterion
C
h
e
c
k
b
e
fo
re
o
p
e
ra
ti
o
n
Shape, Dent, Blot
Visual
Inspection
No dent, blot and deformation
Coating
No looseness
Joint
Meet the criteria
Oil, Coolant
Meet the required level
Wiring
Lead wires to be securely fastened
against
abrasion and damage to bring by
vibration
G
ro
u
n
d
in
g
Continuity
Tester
“GROUNDING” is connected;
-with Engine (bolt for grounding)
-with Bed (bolt for grounding)
-with grounding for Receptacle
Continuity is to be confirmed
I
n
s
u
la
ti
o
n
C
h
e
c
k
Insulation Resistance
DC500V
Mega
Tester
Main Breaker ON.
1-phase breaker (50A) :ON
1-phase breaker (30A) :ON
1-phase breaker (20A): OFF
Disconnect two couplers in AVR.
Disconnect the lead “N”(8mm
2
-Black)
located in the side door.
Remove one side of the output
terminal between engine block and
circuited protector (50A).
Initial excitation winding ~ engine
block (Remove either the lead J or K)
*Insulate all terminals after removal
Over 3MΩ
Dielectric Voltage
Tester
AC1800V (3 sec)
Electric Current: 10mA
It
e
ms
Article
Method
Condition to verify
Criterion
M
o
n
it
o
r
Glow & Monitor
Lamp, Hour Meter
Visual
Inspection
After starter
switch “RUN”
position (
#1
) –
Engine is not
running
Monitor for engine displays “8888” and “8.8.” is displayed
in the fuel monitor.
Glow Lamp
Glow Lamp ON and turns to OFF after 3~7 sec. CHARGE
& OIL PRESS lamps ON. Hour Meter is activated.
Air Filter
AIR FILTER lamp ON when blue and white wires for the
wire harness are grounded.
Fuel Meter
FUEL monitor lamp ON.
Spill Containment
SPILL CONTAINMENT lamp ON when the float switch in
the Spill containment is lifted.
(#2)
Engine is
running
SPILL CONTAINMENT OVERFLOW WARNING lamp ON
and Engine stops when the float switch in the Spill
containment positions lower. (
#2)
Display Selector
Oil press, water temp. and engine speed are displayed in
order when the display selector is pressed each time.
(#3)
Monitor Display
All monitor lamps turns to OFF after engine starts. Hour
meter only is operating.
P
ro
te
c
ti
o
n
C
irc
u
it
Low Oil Pressure
Ground oil pressure wire with a
unit.
OIL PRESS lamp ON and engine stops.
High Water Temp.
Ground water temp. wire with a
unit,
WATER TEMP. lamp ON and engine
stops.
Insufficient battery
charge
Short circuited terminal L (green
wire) from dynamo.
CHARGE lamp ON and engine stops.
Содержание DGK11F
Страница 8: ...5 4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm...
Страница 9: ...6 EXHAUST GAS OUTLET WATER OUTLET...
Страница 10: ...7 5 General Parts Description 5 1 Equipment...
Страница 11: ...8...
Страница 12: ...9...
Страница 16: ...13 Left Side Door Standard Accessory Owners Manual 1 copy Engine Warranty Manual 1 copy Starter Key 1 set 2 pcs...
Страница 30: ...10 Wiring Diagram 27...
Страница 31: ...28...